11.1.2 Backwashing
The water flows through the filter medium in the op-
posite direction whereby the dirt from the sand is
flushed out and is drained via the disposal connection
(2) (which is marked at the corresponding output with
"waste"). This process usually takes 2-3 minutes and
must be carried out until the escaping water is clean
again.
1.
Set the 5-way multi-valve (1) to BACKWASH.
2.
Connect your pool filter system to the mains.
3.
When clean water is conveyed, the backwash pro-
cess is ended which should take about 3 minutes
at most.
4.
Set the 5-way multi-valve (1) to FILTER or RINSE.
11.1.3 Rinsing
Using this process, residual cleaning and compacting
of the filter sand is achieved. The water flows through
the filter sand again from top to bottom. However, it is
then not returned to the pool, but drained through the
disposal connection (2), as in the case with backwash-
ing. This process is carried out after every rinse for ap-
prox. 30 seconds.
1.
Set the 5-way multi-valve (1) to RINSE.
2.
Connect your pool filter system to the mains.
3.
Set the 5-way multi-valve (1) to FILTER.
11.1.4 Emptying
In this position, the water is drained directly via the dis-
posal connection.
Ensure that this position is not suitable for completely
emptying the pool, but is used, for example, to vacuum
the floor after an algae infestation.
1.
Set the 5-way multi-valve (1) to EMPTY.
2.
Connect your pool filter system to the mains.
3.
ATTENTION: Ensure that the filter pump does not
run dry. Operating the pool filter system with too
little or no water can cause damage.
11.1.5 Closing
The water supply from the valve to the filter pump is
closed in this position. This means that only the suc-
tion or skimmer line must be closed for pre-filter cage
cleaning of the pump.
11.2 Commissioning of the pool filter system
Before commissioning, ensure there is a sufficient
water level in the pool (for built-in skimmers up to the
middle of the skimmer), so that water can flow through
the skimmer output downwards to the pool filter system
and completely fills the pre-filter cage of the pump.
If the automatic inflow – is not available, for example in
the event of a suspended skimmer or if the pool filter
system is higher than the water level –, the pre-filter
cap (6) of the filter pump (11) must be opened and man-
ually filled with water before commissioning.
In regular operation, also ensure that there is water
in the filter pump (11) from time to time. Dry running
(without water) for a long time can cause irreparable
damage which is not covered by the warranty.
1.
Set the handle on the 5-way multi-valve (1) to the
BACKWASH position. Only now is the filter pump
put into operation. Carry out the backwash pro-
cess for approx. 2-3 minutes in order to remove
the excess sand from the filter system.
2.
Unplug the pool filter system from the mains and
set the 5-way multi-valve (1) to RINSE.
3.
Connect your pool filter system to the mains. Now
start the rinse process - this takes approx. 30 sec-
onds.
4.
It is best to direct the backwash and rinse water
into the drain or allow it to trickle away onto the
lawn.
5.
Unplug the pool filter system from the mains and
set the 5-way multi-valve (1) to FILTER.
6.
Connect your pool filter system to the mains. The
filter system is now in normal filter operation.
7.
We recommend a filter time of 2 x 4-5 hours per
day in the FILTER position.

12. Electrical connection

The electrical motor installed is connected and ready
for operation. The connection complies with the appli-
cable VDE and DIN provisions.
The customer's mains connection as well as the ex-
tension cable used must also comply with these reg-
ulations.
Damaged electrical connection cable
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
• Pressure points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been improp-
erly fastened or routed.
www.scheppach.com