INSTALLATION

Installation
10. Installation

10.1 Installation location

Observe the following installation location requirements to
ensure correct function.
f Fit the appliance to an internal wall, but not in a recess.
f Never cover the appliance with curtains, etc.
f Ensure the appliance is not directly exposed to external
heat sources (e.g. the sun or central heating).
f Avoid direct draughts coming from windows and doors.

10.2 Preparation

For installation, remove the appliance from the wall mounted
enclosure:
f Release the snap-in tab found in the opening on the un-
derside of the wall mounted enclosure. Press the snap-in
tab with a screwdriver.
f Route a four-core data cable from the heat pump manag-
er to the mounting position of the appliance.
The data cable must protrude 20 to 30 cm out of the wall to
allow installation.
10.2.1 Installation with a flush box
For securing to a wall we recommend using a flush box that
can accommodate the data cable.
f Make sure that the screws supporting the flush box are
arranged either vertically or horizontally opposite one
another.
10.2.2 Installation without a flush box
f To secure the wall mounted enclosure, drill four holes
(Ø 5 mm).
f When routing the data cable, be careful not to damage it
when drilling the fixing holes.
In the area around the cable entry (behind the wall mounted
enclosure), a reservoir needs to be made to hold 20 to 30 cm
of data cable.
14 |
f Break out one of the knock-outs in the wall mounted en-
closure.
f Route the data cable through the hole from the back.
10.2.3 Installing the wall mounted enclosure
1 Flush box
f Secure the wall mounted enclosure to the flush box or to
the wall using the screws provided.

11. Electrical connection

Material losses
Be sure to get the polarity right on the appliance and
on the heat pump manager.
X2
A1
A1
WPM heat pump manager
A2
FEK 2 remote control
A3
Heat pump
1
A3
A2
FEK 2