8. | Working with the Device
²
The adjustment instructions apply in accordance with UN-ECE Regulation no. 48, 53 or 86. For class B and F3 front fog
lights in accordance with UN-ECE (with a luminous flux of ≤ 2000 lumens). If a setting dimension is not specified on the ve-
hicle, the upper limit value is 1.0%, and there are no demands with respect to a lower limit value.
³
For vehicles with a wheelbase less than 2.5 m, load testing is conducted by loading a person on the driver's seat or using
the additive correction value of 0.3 on the setting dimension applicable to the vehicle (e.g. for a setting dimension of 1.2 on
the vehicle, the correction of 0.3 means that the tolerances of +/- 0.5 are applied with reference to the value 1.5).
* see chart in section Performing Headlight Test with a 10-meter Panel [} 135]
** N [cm] dimension by which the center of the light beam is tilted at a distance of 5 m