Elica CT35 PRO Anleitung Zur Installation, Inbetriebnahme Und Wartung Seite 7

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 31
Before making the electrical con-
nections, check that:
-the system ratings meet the ra-
tings indicated on the identifica-
tion plate fixed on the lower part
of the worktop; -the system is
fitted with efficient ground wires
in accordance with the laws and
current standards.
Grounding is mandatory by law.
If the domestic appliance is not
supplied with a cable and/or sui-
table plug, use material suitable
for the absorption value indica-
ted on the identification plate
and the operating temperature. If
wishing to make a direct connec-
tion to the mains, an omnipolar
switch must be installed with a
minimum 3 mm opening betwe-
en the contacts and appropriate
for the load indicated on the pla-
te and in accordance with cur-
rent standards (the yellow/green
ground conductor must not be di-
sconnected by a switch). When
the appliance has been installed,
the omnipolar switch must be ea-
sily reachable.
INSTALLATION
The minimum distance between the cooker
surface and the lower part of the cooker hood
must be 60cm in case of electric cooker and
65 cm in case of gas or mixed kitchens.
If the installation instructions of the appliance for
gas cooking indicate a higher distance, follow the
specific instructions.
Before proceeding with the installation, in order to
avoid damaging the appliance, release the grea-
se filters and the liquid waste tray.
Metal grease filters can be removed by pushing
the filter towards the back side of the hood and
rotating it down, releasing it from its seat (fig. 1).
You can release the liquid waste tray by loose-
ning the screws (fig.2) and pulling out the metal
tray.
Essential requirements before installing the ap-
pliance are the following ones:
- Realization of a suitable opening on the bot-
tom of the cabinet to proper install the applian-
ce (fig. 3).
- Prepare the power supply.
- Prepare an air exhausting hole and the spe-
cific ducting system.
Use an air exhausting duct, whose maximum
length does not exceed 5 m. Limit the number of
bends in the ducting system since every bend re-
duces the suction efficiency of 1 linear meter (e.g.
if you use no.2 bends at 90°, the length of the
ducting system must not exceed 3 meters). Use a
150 mm diameter duct for the whole length.
The material of the duct must be compliant with
the regulations in force.
To install the appliance, adjust the position
of the stop side-springs through the proper
screws (fig. 4), position the brackets 2-3 mm
over the thickness of the cabinet bottom.
Insert the built-in unit in the hole made in
the cabinet until the stop click of the side-
springs. Use the self-tapping screws 3,9x25
for stopping through the internal holes of the
device (fig. 5).
7