5 | Technical data
6
Specification mg/m³ for heated filter method (in compliance with Annexe III, number 4, letter a, sec-
tion i, point 1) or g/kg for measurement in dilution tunnel (in compliance with Annexe III, number 4, let-
ter a, section i, point 2 and 3.)
7
Specifications are made here for the preferred fuel only.
5.2

General specifications

Technical data
Height [mm]
Width [mm]
Depth [mm]
Weight [kg] steel/ceramic/soapstone
Flue pipe outlet, diameter [mm]
Nominal heat efficiency [kW] as per EN test EN 13240
Heat output, minimum [kW]
Maximum heat output [kW]
Space heating capacity, at least (depending on the building insulation) [m³]
Maximum room-heating capacity (depending on the building insulation) [m³]
Minimum clearance from non-flammable materials [mm]
Max. amount of fuel to be deposited [kg] (wood/briquettes)
5.3

Data for the chimney/flue dimensioning

Exhaust gas values for the multiple occupancy of the chimney (according to DIN 4705 Part 3) or rating of the
chimney (according to DIN 4705 Part 2)
Flue gas mass flow [g/s]
Flue gas temperature [°C]
Minimum feed pressure at nominal heat output [Pa] closed
at 0.8 times nominal heat output [Pa]
Safety distances a, b, c [mm]
70
EN
Operating manual Pallas 945029
Basic appliance
900
732
450
170 / 205 / 265
150
9
4.5
13
114
305
50
2.7
9.2
310
12
10
800 / 200 / 200

Werbung

Inhaltsverzeichnis
loading