CONNECTIONS

DMX512 control

DMX Controller
Program
Chase32 Step100
A DMX512 data link is required in order to control the device via DMX. The device provides 3-pin XLR
connectors for DMX connection.
1
Connect the output of your DMX controller to the DMX input DMX IN of the device with a DMX cable.
2
Connect the DMX output DMX OUT of the device to the DMX input of the next unit in the chain. Always
connect one output to the input of the next unit until all units are connected.
3
At the last unit, the DMX cable has to be terminated. Plug the terminator with a 120 Ω resistor between
Signal (–) and Signal (+) in the DMX output of the last unit.
4
If the cable length exceeds 300 m or the number of DMX devices is greater than 32, it is recommended
to insert a DMX level amplifier to ensure proper data transmission.
XLR connection:

Wireless DMX transmission with QuickDMX

The device features an alternative DMX input for a QuickDMX receiver (sold separately). CRMX and WDMX
receivers are compatible and can also be used. The connector allows a DMX control signal to be transmitted
wirelessly to the device, eliminating the need for complex wiring to the DMX controller. The connector is
designed as a USB port which provides the required 5 V operating voltage for the receiver.
Occupation of the USB port:

Connection to the mains

The device uses an auto-range power supply that accepts input voltages between 100 und 240 volts.
1
Connect the device via the enclosed mains cable to a grounded mains socket. Thus the unit is switched
on.
2
To switch off the unit, disconnect the power plug.
3
Do not connect the unit to the mains voltage via a dimmer. For a more convenient operation, use a mains
outlet which is switchable.
Device 1
Starting Address 1
DMX OUT
QuickDMX
FUSE:
POWER IN
T1A/250V
100-240V~
50/60Hz
DMX IN
Device 2
Starting Address 15
DMX OUT
QuickDMX
FUSE:
POWER IN
T1A/250V
100-240V~
50/60Hz
DMX IN
21/28
Device 3
Starting Address 29
DMX OUT
QuickDMX
FUSE:
POWER IN
T1A/250V
100-240V~
50/60Hz
DMX IN