PPM/UDI (S.BUS) mode - method of processing data from the
transmitter
Direct - all receiver settings (e.g. Fail-Safe) are not included in serial
communication
Computed - all receiver settings (e.g. Fail-Safe) are part of serial
communication
Low voltage alarm - setting the threshold for alarm activation
(power supply)

4.1.2 Fail-Safe

If the Fail Safe function is disabled,
there are no signals generated on
receiver outputs in case of signal loss,
either serial communication in "Direct"
mode. When the function is on, all
receiver outputs can be set individually
with the following options:
Repeat: the receiver at the output
keeps the last known value
Turn off the pin: the output is
disabled, no pulse is generated
Fail-Safe: the output is set to the value specified in the "Value"
parameter.
Fail-safe delay: setting the time for which the system goes after
signal loss to Fail-Safe mode.
Set fail-safe position now: when this option is activated, the
current values of the positions are set for all outputs set to "Fail-
Safe" mode.