5. Technical Data

Main power supply
Working Voltage
Receiver board
Installation
Operating Temperature
Dimensions Control Box

6. Troubleshooting

Error
Gate reverses
System learning will not start
Automatic timer cannot be set
Gate opens and closes by itself
N-L appears on the display
after the remote control has
been taught in
-
230V AC, 50Hz/60Hz
24 V DC
433.92 MHz Rolling-Code; memory for 200 transmitters
Wall mounted vertically
-20℃ ~ +50℃ (Mechanics can still freeze at low °C and impair operation)
275 mm x 195 mm x 102 mm
Root cause
1. A & B dimensions not
adhered to.
2. Gate size wrong.
1. Photocell connected
incorrectly or is not
recognized by the control
board.
1. Photocell not found.
1. Installation next to power
line.
1. System is not programmed.
33
Resolutions
1. A & B installation dimensions to align.
Correctly = between 120-190 mm (see
installation instructions).
2. W x H x weight - see technical
specifications on each drive.
1. Check the connection of the photocell
(see page 32).
2. Adjust photocell alignment.
3. If the photocell is not desired (not
recommended), disable function in the
menu.
1. Connect photocell. This function is only
possible with a connected photocell.
1. The controller may not be mounted in
the immediate vicinity of a power line
(electrostatic charge).
1. Perform system learning (see page 26).