Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

4. Photocell Installation

The photocell serves as additional safety device for gate openers. It consists of a transmitter and a receiver and
reacts when the light beam is interrupted.
Technology: Infrared
Range: up to 15 m (rain or fog can reduce the range by up to 30%)
Protection Class: IP45
Power Supply: 12-24 V AC/DC
Wave Length: 940 nm
Working Current: Sender ≤15 mA – Receiver ≤30 mA
Working Temperature: -20°C - +60°C
Relay Contact: 1 A max. 30 V/ DC
Dimensions: 73 x 43 x 25 mm
Article Number: ST201008
Model Number: SPCM
Receiver
Infrared
Indicator
Photocell
outputs
Installation:
• Receiver:
o Connect the 12-24VAC/DC ports to PhVcc and GND
o Connect the COM port to Ph1
o Connect the NC port to GND
o The NO port is not used.
• Sender:
o Connect the 12-24VAC/DC ports to PhVcc and GND
Sender
32
19 20 21 22 23 24 25 26
DKey SKey GND Ph1 PhVcc GND Ph2 PhVcc
-
+
NO NC
COM
12-24V AC/DC
Receiver
Photocell
-
+
12-24V AC/DC
Sender