LED Display
Definition
FC
Photocell 1 function
FD
Photocell 2 function
FE
Buzzer function
FF
Latch release
function (electric lock)
Open/Stop/
FG
Close/Stop
function key
FH
Pedestrian
Mode function
key
FI
Reverse option
when closing
FJ
Reverse option
when opening
FK
Functions of D
Key terminal
FL
Functions of S
Key terminal
Parameter
FC-0
Function OFF
FC-1
Function ON
FD-0
Function OFF
FD-1
Function ON
FE-0
Function OFF
FE-1
Function ON
Function OFF
FF-0
Function ON
FF-1
FG-1
A Key
FG-2
B Key
FG-3
C Key
FG-4
D Key
FH-0
Function OFF
FH-1
A Key
FH-2
B Key
FH-3
C Key
FH-4
D Key
When in Motor type setting F1-3 (factory setting):
FI-1
Reverse 2 seconds when not detecting hall sensor or over-current
occurs before reaching closing position.
When in Motor type setting F1-1 (not factory setting): Reverse
2 seconds within 80% of total stroke.
FI-2
When in Motor type setting F1-3 (factory setting):
Reverse 4 seconds when not detecting hall sensor or over-current
occurs before reaching closing position.
When in Motor type setting F1-1 (not factory setting):
Reverse to the end within 80% of total stroke.
When in Motor type setting F1-3 (factory setting):
FI-3
Reverse to end when not detecting hall sensor or over-current
occurs before reaching closing position.
When in Motor type setting F1-1 (not factory setting):
Reverse to the end within 90% of total stroke.
When in Motor type setting F1-3 (factory setting):
FJ-1
Reverse 2 seconds when not detecting hall sensor or over-current
occurs before reaching opening position.
When in Motor type setting F1-1 (not factory setting):
Reverse 2 seconds within 80% of total stroke.
FJ-2
When in Motor type setting F1-3 (factory setting):
Reverse 4 seconds when not detecting hall sensor or over-
current occurs before reaching opening position.
When in Motor type setting F1-1 (not factory setting):
Reverse to the end within 80% of total stroke.
When in Motor type setting F1-3 (factory setting):
FJ-3
Reverse to end when not detecting hall sensor or over-current
occurs before reaching opening position.
When in Motor type setting F1-1 (not factory setting):
Reverse to the end within 90% of total stroke.
FK/L-1
Double gates (Open/Stop/Close/Stop)
FK/L-2
Single gates (Open/Stop/Close/Stop)
FK/L-3
Pedestrian mode
Open
FK/L-4
FK/L-5
Stop
Close
FK/L-6
No Function
FK/L-7
Table
30
Description
1. The factory setting is "FC-1".
1. The factory setting is "FD-0".
1. The factory setting is "FE-0".
1. When function is active, gate
moves slightly forward to
unlock the lock.
2. The factory setting is "FF-0".
1. The factory setting is "FG-1".
1. The factory setting is "FH-2".
1. FI factory setting "FI-3".
1. FJ factory setting is "FJ-1".
1. FK factory setting "FK-1".
2. FL factory setting is "FL-2".