Safety Notes

� Gloves should be worn during installation to prevent crushing and cutting
injuries.
� The product may only be used for bathing, hygienic and body cleaning
purposes.
� Children as well as adults with physical, mental and/or sensoric impairments
must not use this product without proper supervision. Persons under the
influence of alcohol or drugs are prohibited from using this product.
� The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
• The pipes and the fixture must be installed, flushed and tested as per the
applicable standards.
• The plumbing codes applicable in the respective countries must be observed.
Special information for UK
If installing this product with a pump, please be aware that it has to have negative
head switching. This product will not function with a positive head pump.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
• Safety against backflow
• The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Safety Function (see page 38)
The desired maximum temperature for example max. 42º C can be pre-set thanks
to the safety function.
Adjustment (see page 37)
After the installation, the output temperature of the thermostat must be checked. A
correction is necessary if the temperature measured at the output differs from the
temperature set on the thermostat.
Fault
Insufficient water
Crossflow, hot water being forced into cold water
pipe, or vice versa, when mixer is closed
Spout temperature does not correspond with
temperature set
Temperature regulation not possible
Safety stop button not operating
Valve stiff
Shower or spout dripping
Pushbutton cannot be actuated or is without function
Pushbutton is jammed or stiff
Pushbutton does not snap in
4
English
• The check valves must be checked regularly according to DIN EN 1717 in
• To guarantee the smooth running of the thermostat, it is necessary from time to
Minor leaking may occur briefly during initial commissioning and interruption/
max. 1 MPa
restart of the water supply.
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 70°C
65°C
max. 70°C / 4 min
Cause
- Supply pressure inadequate
- Regulator filter dirty
- Shower filter seal dirty
- Backflow preventers dirty or leaking
- Thermostat has not been adjusted
- Hot water temperature too low
- Temperature regulator dirty or calcified
- Spring defective
- Button calcified
- Select stop valve DN9 damaged
- Select stop valve DN9 damaged
- Safety guard of isolating valve has not been
removed
- Seal needs greasing
- Select Adapter incorrectly trimmed
Assembly (see page 34)
Maintenance (see page 38)
accordance with national or regional regulations (at least once a year).
time to turn the thermostat from total hot to total cold.
Dimensions (see page 31)
Flow diagram (see page 31)
free flow
Outlet 1
Shower outlet
Spare parts (see page 41)
+
Special accessories (see page 41)
order as an extra
Cleaning (see page 40)
Installation example (see page 32)
i
Operation (see page 40)
Test certificate (see page 44)
Remedy
- Check water pressure (If a pump has been installed
check to see if the pump is working).
- Clean filter in front of the mixer and on the MTC-ther-
mo cartridge
- Clean filter seal between shower and hose
- Clean backflow preventers, exchange if necessary
- Adjust thermostat
- Increase hot water temperature to 42 ºC to 65 ºC
- Clean temperature regulator, exchange if necessary
- Clean spring and/or button, exchange if necessary
- Exchange Select stop valve
- Exchange Select stop valve
- Remove safety guard from isolating valve
- Grease the seal
- Trim and mount Select Adapter according to Fig.
7 (see page 34)
- First, fully press the pushbutton down into the rosette;
then, mount the rosette

Werbung