4.2 Automatic configuration

4.3 Manual programming of movement and slowdown

Manual configuration can be carried out using a button connected to terminals 6 - 10 (Step-by-step) or by
means of a previous programmed remote transmitter (remote control device), see chapter 5.1.
- Press and hold the START button for 5
seconds until all the five red LEDs start
flashing.
- Press the START button against in order
to start the initial configuration sequence.
If the gate starts opening, press the
START button again to move it back (the
first movement of the gate needs to be in
the closing direction).
The first limit switch activated needs to be
a closure switch.
The automation performs the following in
sequence: closing (1), opening (2), closing
(3), opening (4). After the initial
configuration is completed, two green
LEDs will start flashing and a red LED (on
the left side) will become lit).
If the result obtained is not satisfactory,
start the procedure anew.