Manual Release; Cabling And Connections - EasyWay 110 Benutzerhandbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 50

2.4 Manual release

CAUTION:
• Before proceeding, turn of the power supply from the grid.
• Manual release may result in uncontrolled gate movement due to mechanical damage or unbalanced
mechanical conditions.
• This command enables releasing the motor gearbox and moving the gate wing manually. It can be used
in the even of power supply shortage or incorrect functioning of the automation.
Manual release is performed using the key (2) included in the set. It is important to store the key in a safe
place.
a) Move the lock guard (1) to the right.
b) Insert the key (2) to the lock and turn it 180° left.
c) Open the cover by pulling it gently.
d) The automation will become unlocked then (3).

2.5 Cabling and connections

Before continuing with making the connections it is necessary to read carefully the sections devoted to
SAFETY.
All the activities regarding cabling and connections must be carried out when the control panel is
disconnected from the power supply.
Power supply
Power supply cable
Cable type
3x1.5 mm
2
cable
30