3. Specifications / 4. Design and function
Electrical contact
Type of contact
Contact functions
Load data
U max.
I max.
P max.
Switch point setting
Setting range
Switch point
reproducibility
Switch hysteresis
Electrical connection
For further specifications see the corresponding product label, WIKA data sheet
and the order documentation.

4. Design and function

4.1 Description
The ⊕ and ⊖ media chambers
are separated by an elastic dia-
phragm. The differential pres-
sure leads to an axial deflection
of the the diaphragm against
the measuring range spring.
The deflection, which is
proportional to the differential
pressure, is transmitted to
a movement and in addition
to the plungers of the micro
switches via a pressure-tight
and low friction link.

4.2 Scope of delivery

Cross-check scope of delivery with delivery note.
WIKA operating instructions differential pressure gauge, model 702.03.100
Micro switch
Single (change-over) contact
850.3
Voltage AC
250 V
5 A
250 VA
from the outside at assistant scale by means of adjustment
screw(s)
from 10 % to 100 % of the full scale value
≤ 1.6 %
max. 5 % of the full scale value (option: max. 2.5 %)
via cable gland M20 x 1.5 with 1 m free cable end
Double (change-over) contact
850.3.3
Voltage DC
30 V
0.4 A
10 W
GB