Herunterladen Inhalt Inhalt Diese Seite drucken

Tr4000 4 Et I Tr4000R 4 Et; Płukanie Rozruchowe; Regulowanie Temperatury; After Installation - Bosch TR4000 Montage- Und Gebrauchsanleitung

Vorschau ausblenden Andere Handbücher für TR4000:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

After installation

3
After installation
3.1

TR4000 5 ET, TR4000 6 ET, TR4000 6 EB,

TR4000 8 ET and TR4000 8 EB
(fixed electrical connection)
Switch on the fuses.
3.2
TR4000 4 ET and TR4000R 4 ET
Insert the plug into the mains socket.
First start-up
(Fig. 6)
3.3

Initial rinsing

Open the warm water tap and allow water to flow for at least
1 minute (flow-rate at least 2 litres per minute). Only then
(for safety reasons) will the appliance begin to heat.
Info: The appliance will not heat if the dispensed water flow is
interrupted prematurely. Open the warm water tap again and
allow water to flow for at least 1 minute.
4

Technical data

Type
Design
Power
Electrical connection
Minimum cable cross-section [mm²]
Rated current
Fuse protection
Water connection thread
Supply temp. max.
Warm water output at supply
temp. of 12 °C to 38 °C
Protection type
Switch on flow pressure
(without flow rate limiter)
Switch on flow
Switch off flow
18
TR4000 4
ET
TR4000R 4
ET
Undersink
pressurised pressurised pressurised pressurised pressurised pressurised
[kW]
3,6
[V]
230
1,5
[A]
15,7
[A]
16
[Inch]
G 3/8
[°C]
20
[l/min]
1,9
IP
24
[bar]
< 0,3
[l/min]
1,8
[l/min]
1,6
Tip: Should the appliance not start because of a reduced flow-
rate, remove the perlator, aerator or similar before starting and
repeating the process.
Important: If the continuous-flow heater does not have
sufficient water flow due to low water line pressure in your
domestic plumbing system:
Switch off the circuit-breakers/fuses or remove the mains
plug.
Remove the flow-rate limiter (H1–H4).
3.4

Controlling temperature

The supply temperature (probably lower in winter) and
pressure fluctuations can influence the temperature of the
water leaving the tap (see Fig. 4, left: pressurised [closed],
right: unpressurised [open]).
Turn the valve slowly in the closed direction for higher
temperatures (F1).
Add cold water for lower temperatures (F2).
Hand over the installation and operating instructions
to the user and explain how the appliance operates.
TR4000 5
TR4000 6
ET
ET
Undersink
Undersink
4,5
6
230
230
2,5
4
19,1
26
20
32
G 3/8
G 3/8
20
20
2,4
3,2
24
24
< 0,3
< 0,3
1,8 / 1,9
1,8 / 2,1
1,6 / 1,7
1,6 / 2,0
TR4000 | TR4000R – 6720876021 (2022/04)
TR4000 8
TR4000 6
ET
EB
Undersink
Over-sink
7,2
6
230
230
4
4
31,3
26
32
32
G 3/8
G 1/2
20
20
3,9
3,2
24
24
< 0,3
< 0,3
1,8 / 2,3
1,8 / 2,1
1,6 / 2,2
1,6 / 2,0
TR4000 8
EB
Over-sink
7,2
230
4
31,3
32
G 1/2
20
3,9
24
< 0,3
1,8 / 2,3
1,6 / 2,2

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis