Power Circuit ADJUSTMENT
ADJUSTMENT OF Output Voltage Confirm
Measuring
Digital Voltmeter
instrument
Item
Test point
AT 12V
AT between 12Vline~GND
AT 5V
AT between 5Vline~GND
AT 39V
AT between 39Vline~GND
AT 25.0V AT between 25.5Vline~GND DC 25.0V±0.5V
<Setting Condition>
1. Power Supply : AC190V(50Hz)
2. SURROUND temperature Setting : 20ºC±10ºC
3. load connect place : between AT 5V→AC connector
8PIN~AC connector1PIN
(High speed) : between AT25.5V→AC5PIN~AC2PIN
(Other model) : between AT12V→AC5PIN~AC2PIN
ADJUSTMENT OF Over Load Characteristic
Confirmation
Measuring
Osiloscope
instrument
Item
Test point
AT 12V
AT between 12Vline~GND
AT 25.0V AT between 25.5Vline~GND Output above 25.0V
when apply the over load at the AT12V/AT25.5V output for
every 170msec, confirm that the output is 11.0V/25.0V for every
time.
(A)
2.2A
0.65A
70
100
Specification Fix Load
DC 12.5V±0.3V
360mA+actual load
DC 5.25V±0.1V
18mA+actual load
DC 39.0V±2.0V
actual load
actual load
Specification
Fix Load
Output above 11.0V 2.0~2.2A(over load)
(msec)
ADJUSTMENT OF Power Consumption Con-
firmation
Measuring
Power Consumption device
instrument
Mode
Power off
Fix Load
actual load
Test point
AC Plug
Specification
3.0W MAX
1.Power supply : AC230V(50Hz)
2.Surround Temperature Setting : 20ºC±10ºC
IGR(MPX) Circuit ADJUSTMENT
ADJUSTMENT OF Separation Confirmation
Test point
RCA AUDIO OUT
Specification
R-Lch more than 30dB
1. Receive the IGR Bilingual Broadcasting (STEREO).
(Signal content L-ch
(Signal content R-ch
2. Connect the RCA AUDIO out put L-ch to Voltmeter.
(weight : flat)
34
±0kHZ dev)
400Hz 0±50kHz dev)