GENERAL SAFETY WARNINGS

The Operation Manual is an integral part of the product and so must be
carefully preserved in order to accompany the product; if it is lost or da-
maged another copy can be requested from Morco Products Limited on
01482 325 456 or visit our website www.morcoproducts.co.uk.
The installation of the device and any other repairs or mainte-
nance must be performed by Gas Safe Engineer or other qualified
personnel according to the law in force, in compliance with the
installing regulations including any revisions.
A Gas Safe Engineer or other qualified personnel must commission
this device.
The device must be used according to the manufacturer specifica-
tions. The manufacturer cannot be held contractually or otherwise
responsible for damage caused to persons, animals or objects as a
result of incorrect installation, repair or maintenance or improper
usage.
The product's safety or automatic regulation devices must not be
modified unless performed by the manufacturer.
This device is intended for heating water and therefore must be
connected to a water distribution network who's load and settings
are compatible with the product.
If water leaks are observed, turn off the water supply and advise a
Gas Safe Engineer or other qualified personnel.
If the appliance is not used for prolonged periods turn off the gas
supply. If there is a risk of the water freezing, empty the water he-
ater. Please see "frost and freezing" on page 7.
If the machine breaks down or does not function properly, deacti-
vate it, do not attempt to perform any repairs and contact a Gas
Safe Engineer or other qualified person.
The appliance should be maintained at least once a year.
When the product has reached the end of its serviceable life, it
shall be disposed of in an environmentally friendly way; ensuring
that the majority of the product is fully recycled
When using the device the following safety rules must be applied:
Do not use the machine for purposes other than those intended by
the manufacturer.
Do not block the intake, flue or the ventilation openings in the
area where the device is installed with rags, paper or any other
materials.
If a gas leak is detected, do not switch on any electrical devices, te-
lephones or any other objects that could produce a spark. Ventilate
the area by opening the doors and windows and switch off the gas
supply.
Do not place objects on top of the device.
Do not leave flammable containers or substances in the area whe-
re the device is installed.
Children or inexperienced persons are prohibited from using the
device.

DESCRIPTION OF THE APPLIANCE

The Morco EUP6 and EUP11 are an open flued 6 and 11 litre
instantaneous gas water heater.
The air for combustion comes from the external vents in the
cupboard that the heater is placed in and hence very careful atten-
tion must be paid to providing sufficient ventilation.
See section Room Ventilation.
The appliance is suitable for use in dedicated boiler cupboards in
caravan holiday homes.
The appliance relies on a pilot flame to ignite the main burner
once a hot tap is opened.
The appliance does not store hot water.
The flow of the water through the appliance can be adjusted from
3 to 6 litres per minute (EUP6 model) and 5.5 to 11 litres per mi-
nute (EUP11 model) and this corresponds to the temperature of
the incoming water being increased by 50°C or 25°C respectively.
This adjustment is made via the water temperature adjustment
knob and during winter months it is advisable to move the knob
fully clockwise to ensure hot water of an acceptable temperature.

INSTALLATION

Regulations

The use of gas devices is controlled by precise regulations.
Installation of liquid petroleum gas (L.P.G) must comply with all the ma-
nufacturer's requirements and those of the regulations.

Wall mounting

Warning
Do not install this device in an area that contains dust, greasy vapour and/
or corrosive elements.
- The device must be installed on a suitable wall surface that allows the
fitting of a vertical exhaust gas flue
- It is vital to leave the minimal distances around the device as shown in
fig 2 (pag. 33) to allow for maintenance operations to take place.
Location
The water heater requires a plentiful supply of fresh air for correct ope-
ration. Fixed ventilators or air inlets should not be obstructed.
Do not install the water heater in a location where incomplete combu-
stion is foreseeable such as bathrooms or bedrooms unless specifically
allowed by national legislation.
The minimum low and high level free ventilation areas are stated on this
page and must be observed.
The water heater must be fixed to a load bearing wall in a vertical
plane.

Room ventilation

The installation of the water heater must comply with regulations in for-
ce including any updates (see page 4).
Warning: This device can only be installed in venues that are permanently
ventilated according to regulation in force.
• COMBUSTION GAS REMOVAL
A single wall vertical flue pipe of Ø90 (for EUP6) and Ø110mm (for
EUP11) must be used and when it passes through combustible materials,
a metal sleeve of Ø170mm must be used to allow an air gap of 25 mm.
Part codes FTFCT (for EUP6) and FTFCTRIMG101 (for EUP11).
Flue pipes and terminals should comply with BS 715. Terminals shall not
be sited within 300 mm. of a ventilator or open window. In the U.K. full
details of flueing requirements are given in BS EN 1949.
The overall length of the flue must be 600mm from the bottom of the
terminal louvres to the top of the water heater. At least 250mm of this
length must be external to the roof through which it is fitted.
• AIR SUPPLY FOR COMBUSTION
Air requirements: Reference is made to BS EN 1949 and EN 721 covering
ventilation requirements for permanent dwellings, caravans and boats.
Fixed ventilation should be provided to avoid draughts as far as possible
without impairing the free area of ventilation, even in ad- verse weather
conditions. If the heater is positioned in location which may be subjected
to strong draughts i.e. close to a window or opening then strong draughts
or gusts of wind may extinguish the pilot.
All permanent openings for ventilation should be designed to pre- vent
the entry of vermin. Where screens are provided, they should not have
apertures of less than 6 mm. or greater than 9 mm. in any direction, and
they should be accessible for cleaning. Fine mesh screens shall be avoided
as they are liable to become blocked with dust.
The location of vents and the method of cleaning them should be stated
in the Owners Handbook (Caravans and Boats).