Safety distances

-
The heater must be installed at a minimum height of 180 cm.
-
If installed in a toilet, the height should be 225 cm in zone 1 and
zone 2; in zone 3 the minimum above ground level is 180 cm,
according with the rules of each Country.
-
A minimum air gap of 30 cm should always be allowed between
the top of the heater and a ceiling or roof. The appliance should
be 50 cm far from the walls
-
The heater must not be directed towards the ceiling or
flammable materials.
-
The device must not be mounted into the ceiling. You must
leave enough space around the top of the unit to ensure good
ventilation.
-
Do not use the heater in close proximity of a bath, shower or
swimming pool.
-
If there is nobody in the room to be heated, it is recommended
to turn off the unit.
-
Avoid exposing skin to the rays of the appliance for distances
less than 30 cm.
-
Avoid exposing eyes to the rays of the appliance for distances
less than 1.80 m.
30cm
180cm
50cm
27
50cm