Herunterladen Inhalt Inhalt Diese Seite drucken

Safety Precautions - Acson international C-Serie Montageanleitung

Vorschau ausblenden Andere Handbücher für C-Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 31
INSTALLATION MANUAL
This manual provides the procedures of installation to ensure a safe and good standard of operation for the air
conditioner unit.
Special adjustment may be necessary to suit local requirement.
Before using your air conditioner, please read this instruction manual carefully and keep it for future reference.
This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for
commercial use by lay persons.
This appliance is not intended for use by persons, including children, with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
! WARNING
Installation and maintenance should be performed by
qualified persons who are familiar with local code and
regulation, and experienced with this type of appliance.
All field wiring must be installed in accordance with the
national wiring regulation.
Ensure that the rated voltage of the unit corresponds to
that of the name plate before commencing wiring work
according to the wiring diagram.
The unit must be GROUNDED to prevent possible hazard
due to insulation failure.
All electrical wiring must not touch the water piping or any
moving parts of the fan motors.
Confirm that the unit has been switched OFF before
installing or servicing the unit.
Risk of electric shock, can cause injury or death. Disconnect
all remain electric power supplies before servicing.
DO NOT pull out the power cord when the power is ON.
This may cause serious electrical shocks which may result
in the fire hazards.
Keep the indoor and outdoor units, power cable and
transmission wiring, at least 1m from TVs and radios, to
prevent distorted pictures and static. {Depending on the
type and source of the electrical waves, static may be heard
even when more than 1m away}.
Disposal requirement
Your air conditioning product is marked with this symbol. This means that electrical and electronic products shall not
be mixed with unsorted household waste.
Do not try to dismantle the system yourself: the dismantling of the air conditioning system, treatment of the refrigerant,
of oil and of other parts must be done by a qualifi ed installer in accordance with relevant local and national legislation.
Air conditioners must be treated at a specialized treatment facility for re-use, recycling and recovery. By ensuring this
product is disposed of correctly, you will help to prevent potential negative consequences for the environment and human
health. Please contact the installer or local authority for more information.
Batteries must be removed from the remote controller and disposed of separately in accordance with relevant local and
national legislation.

SAFETY PRECAUTIONS

Please take note of the following important points when
installing.
Ensure that the drainage piping is connected properly.
If the drainage piping is not connected properly, it may
cause water leakage which will dampen the furniture.
Ensure that the unit's panel is closed after service or
installation.
Unsecured panels will cause the unit to operate
noisily.
Sharp edges and coil surfaces are potential locations
which may cause injury hazards. Avoid from being in
contact with these places.
Before turning off the power supply set the remote
controller's ON/OFF switch to the "OFF" position to
prevent the nuisance tripping of the unit. If this is not done,
the unit's fans will start turning automatically when power
resumes, posing a hazard to service personnel or the user.
Do not install the units at or near doorway.
Do not install the units at area like hot spring or oil
refinery plant where sulphide gas exists.
Do not operate any heating apparatus too close to the
air conditioner unit or use in room where mineral oil,
oil vapour or oil steam exist, this may cause plastic
part to melt or deform as a result of excessive heat or
chemical reaction.
When the unit is used in kitchen, keep flour away from
going into suction of the unit.
This unit is not suitable for factory used where cutting oil
mist or iron powder exist or voltage fluctuates greatly.
Ensure the color of wires of the outdoor unit and
the terminal markings are same to the indoors
respectively.
IMPORTANT : DO NOT INSTALL OR USE THE AIR
CONDITIONER UNIT IN A LAUNDRY ROOM.
Don't use joined and twisted wires for incoming power
supply.
The equipment is not intended for use in a potentially
explosive atmosphere.
NOTICE
1-5
! CAUTION

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis