INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS FOR COOKER HOOD
MODEL OPERA 230-240 Vac - 50 Hz
 
 
Exhausting cooker hood. The equipment is constructed in accordance with European Standards and with the requirements included in
the following Directives: 2006/95EC ( Low Voltage Directive), 2004/108 (Electromagnetic Compatibility).
 
 
 
 
The unit (Picture 1) is composed of the following elements:
1) Cooker hood body
2) Telescopic chimney
3) Perimetric glass
 
Read the instruction manual before installing and/or using the hood.
The unit must be fitted at a distance of at least 65 cm. from the cooking hob. If the mounting instructions of the gas cooker indicate a wider
distance, respect it. The unit must not be mounted above cookers fitted with top radiant plate.
Respect all the air discharge regulations.
The air must not be discharged in a pipe used to discharge exhaust fumes produced by gas-fed equipments or fuel-fed equipments (this
does not apply to filtering hoods).
The room must be adequately ventilated when the hoods is used together with other gas-fed or fuel-fed equipments.
For an easy access, it is advisable to move possible furniture under the installation area.
Installation of the hood onto the wall.
The hood is equipped with all the necessary fastenings for its installation, which are suitable for most surfaces.
Verify that the installation surface is strong.
Installation must be carried out by qualified installers according to present regulations.
1) Draw and drill the wall as in Picture 2
2) Fix on the wall the screw anchors with its support (A).
3) Fix with screw anchors (C) the support of the telescopic chimney (B).
4) Put the screw anchors on the holes (D)
5) Fix the hood to the screw anchors see point 2), two people are needed for this operation.
6) Block the equipment with screws (E), to reach these fastenings (Pic. 3-H) open the panel (Pic. 3-I).
7) Apply the pipe and/or the drain connection.
8) Fix the telescopic chimney on the vents on the upper part of the hood and fix it to the support with screws (F).
This equipment must be connected to a grounding plant.
Two types of electrical connection can be used:
1) Using a standard plug to be connected to the power cable and inserted in a mains socket which must be accessible (so that the plug can
be disconnected when servicing is carried out). Make sure that the plug is accessible also after the complete installation of the equipment.
2) By means of a fixed mains connection, fitting a bipolar switch, which ensures the disconnection, with an opening distance of the contacts
allowing a complete disconnection on the conditions of the overvoltage III category, according to installation regulations. The ground
connection (yellow-green wire) must not be interrupted.
Refer to the plate inside the hood for the mains voltage and frequency ratings.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid
a hazard.
 
This cooker hood can be employed as exhausting or filtering.
Exhausting (external evacuation). Kitchen smokes are driven outside through a flue joined to the exhaust pipe flue connector.
This pipe must not under any circumstances be connected to cooker, boiler or burner exhaust pipes, etc.
Filtering (inside recycling). Smokes pass through the activated charcoal filter (Picture 3 - G) to be cleaned and recycled in the kitchen
environment by means of holes from which the purified air will come out. These holes have to be free and communicating with the kitchen
environment.
In this case you should not install the exhaust pipe without curve.
 
 
 
 
The hood is supplied with a multispeed motor.
The hood should be run at low speed under normal conditions and at higher speeds only when there is a heavy build-up of fumes or
odours.
Ideally, the hood should be switched on as soon as cooking is started and then kept on until all odours have been eliminated.
For the identification of the bottons, refer to the following figure:
- TL: illumination on and off
- T1: switching on the hood, selection of the first speed, aspirator shutdown
- T2: selection of the second speed of the aspirator
- T3: selection of the third speed of the aspirator
- T4: selection of the Booster (maximum suction), the aspirator remains for 5 minutes at this speed (with flashing button) and then it will
automatically switch to the third speed.
- T5: activation and deactivation of the 24h Comfort function
 