Installation
- Plaster and tile the wall, excluding the area occupied by the
mounting template. Seal any apertures in the wall so that they
are watertight to spray water.
• Tiles laid in mortar should be pointed so that the joint is
tapered towards the outside.
• Seal prefabricated walls with a permanently plastic
compound.
- Remove the mounting template, see fig. [1].
- Unscrew adjusting nut (F). Detach stop ring (J) and re-fit after
rotating it clockwise through 90°, see fig. [1].
- Screw in adjusting nut (F) and fit sleeves, see fig. [1].
Flush out the pipelines.
- Unscrew and remove non-return valve (A), see fig. [2].
- Insert flushing plug (B) in vacant non-return valve aperture, see
fig. [3].
- Open the hot and cold water supplies and flush out the pipes
thoroughly.
- Close the hot and cold water supplies, remove plug (B) and
install non-return valve (A).
- Attach cover plate (C) with screws (D) and mount flow control
knop (E), see fig. [4].
If the thermostat has been installed at too great a depth, this
can be adjusted by 27.5mm with an extension set (see fold-out
page II, ref. No. 47 172).
If the thermostat has been installed at too shallow a depth, this
can be adjusted by 20mm with an compensation ring (see fold-out
page II, ref. No. 08 935 or 08 936).
Reversed union (hot on right - cold on left).
Replace thermoelement (M), see replacement parts
fold-out page II, ref. No.: 47 282 (1/2").

Adjustment

Installation of the thermostat knob and temperature
adjustment, see figs. [5] and [6].
• Before the mixer is put into service if the mixed water
temperature measured at the point of discharge varies from the
specified temperature set on the thermostat.
• After any maintenance operation on the thermoelement.
1. Open the shutt-off valve and check the temperature of the water
with a thermometer, see fig. [5].
2. Turn the adjusting nut (F) clockwise or anticlockwise until the
water temperature reaches 38 °C, see fig. [5].
3. Install thermostat knob (G) in such a way that the 38 °C mark on
the knob coincides with the mark (H) on the wall plate, then
tighten screw (I) securely, see fig. [6].
Temperature limitation
The safety stop limits the temperature range to 38 °C.
If a higher temperature is desired, the 38 °C stop can be overridden
by pressing in the safety stop.
Prevention of frost damage
When the domestic water system is drained, thermostat mixers
must be drained separately, since non-return valves are installed in
the hot and cold water connections.
The complete thermostat assemblies and non-return valves must
be unscrewed and removed.
M
aintenance
For maintenance, see fold-out page II.
Shut off hot and cold water supplies.
I.Thermoelement
1. Remove screw (I) and pull off thermostat knob (G).
2. Pull off flow control knop (E).
3. Remove screws (D) and wall plates (K) or (L).
4. Remove adjusting nut (F).
5. Pull off stop ring (J).
6. With a 24mm open-ended spanner, unscrew and remove
thermoelement (M).
II.Non-return valve
1. Proceed as for maintenance of thermoelement, points 1 - 3.
2. Unscrew and remove non-return valve (N) with 17mm socket
wrench.
III.Ceramic headpart
1. Proceed as for maintenance of thermoelement, points 1 - 3.
2. Unscrew and remove sleeve (P).
3. With a 17mm open-ended spanner, unscrew and remove
ceramic headpart (R).
Inspect and clean all parts, replace if necessary and grease with
special valve grease (ref. No. 18 012).
Reassemble in the reverse order.
Replacement parts, see fold-out page II ( * = special accessories).
Readjustment is necessary after every maintenance operation on
the thermoelement (see Adjustment).
Care
For directions on the care of this thermostat mixer, please refer to
the accompanying Care Instructions.