8
CPU BOARD DESCRIPTION
CPU BOARD LAYOUT KEY
OPER
GREEN LED
COM
GREEN LED
A
+3V3
RED LED
CLOUD
GREEN LED
RUN
RED LED
B
PWR
RED LED
DIP switch ON = Maintenance in progress
SW2-1
DIP switch OFF = Normal operation
DIP switch ON = Reset codes
SW2-2
DIP switch OFF = Normal operation
C
DIP switch ON = Total reset
SW2-3
DIP switch OFF = Normal operation
DIP switch ON = Not allowed
SW2-4
DIP switch OFF = Normal operation
D
RES
Reset button if pressed for 5 sec
E
EXC
Jumper inserted = Tamper bypassed
F
TAMPER Tamper connector
+BAT
Back-up battery connection cable
G
12 V⎓ 7Ah
-BAT
+PS
Board power positive (14,4 V⎓)
H
-PS
Board power negative (GND)
USB connector type B. For local connection of a
I
USB-B
PC for programming
RJ45 connector. For connecting the control unit
J
LAN
to a LAN or modem/router
K
OPTO 1 Connector for optional interface
L
OPTO 2 Connector for optional interface
M
OPTO 3 Connector for optional interface
* For connection of the ER3000-RF wireless expansion
EN50131
EN 50131 grade 2 certified device
GRADO 2
3.

ASSEMBLING THE INTERFACES IN THE CONTROL PANEL

Assemble the required interface boards on the CPU board. Up to three interfaces, not more than one
per type, can be installed:
IT3000-PSTN, telephone line interface (max 1, preferably on OPT1);
IT3000-2G, GSM interface, or IT3000-4G, 4G interface (max 1, preferably on OPT2);
ER3000-WIFI (max 1) and ER3000-ZB (max 1, preferably on OPT3).
IMPORTANT!
The interfaces must be inserted and removed with the control panel not powered (mains and battery
disconnected).
On = Normal operation
Flashing = System start
Flashing = Normal operation
Logic present power (+3,3 V⎓)
On = Cloud connected
Flashing = Normal operation
Board power supply present
(14,4 V⎓)
N
BUS
RED LED
+
Power positive (13,8 V⎓)
O*
A / B
BUS Data transmission/reception A / B
-
Power negative (GND)
+
Power positive (13,8 V⎓)
P
A / B
BUS Data transmission/reception A / B
-
Power negative (GND)
SR
Power output without back-up (14,4 V⎓)
+V1
Power output positive (13,8 V⎓)
-V1
Output power negative (GND)
Q
NC1
Output 1 - relay, contact normally closed
NO1
Output 1 - relay, normally open contact
C1
Output 1 - relay, common contact
U2
Output 2 - electric
SAB
SAB input - single-balanced
+V2
PrIO power positive (13,8 V⎓)
-V2
PrIO power negative (GND)
IN1
Input 1, referred to positive
R
IN2
Input 2, referred to positive
IN3
Input 3, referred to positive
IN4
Input 4, referred to positive
IN5
Input 5, referred to positive
IN6
Input 6, referred to positive
+V2
Power positive (13,8 V⎓)
-V2
Power negative (GND)
S
P7
PrIO 7 – programmable input/output
P8
PrIO 8 – programmable input/output
Flashing = Bus communication