17.1 Cleaning

Clean the machine and the working attachment from soil, dust, grass, chips, and small twigs, etc.
The use of solvents, harsh chemicals or abrasive cleaners leads to damage to the machine!
Therefore: When cleaning, use only mild detergent.
The use of high pressure cleaners is not recommended. It shortens the service life and reduces
the operational integrity. (Water can get into the gear!)
Impregnate bare surfaces of the machine against corrosion (e.g., anti-rust WD40).
17.2

Maintenance

The machine does not require extensive maintenance. If malfunctions and defects occur, let it be serviced
by trained persons only.
Only a properly maintained equipment may be a satisfactory tool. Care and maintenance
deficiencies can cause unpredictable accidents and injuries.
Repairs should be performed only by authorized service centers.
Improper operation may damage the equipment or endanger your safety.

17.3 Maintenance plan

Grease / cleaning the ram
Check oil level
Change hydraulic oil

17.4 Hydraulic oil change

Check the oil level regularly. Change the hydraulic oil completely at least once a year.
Always dispose of used oil correctly and never throw it into household waste or sewage!
The hydraulic system of the log splitter is a closed system with oil tank, oil pump and control valve. The oil
should be changed completely once a year.
The following hydraulic oils are recommended for the hydraulic transmission system of the log splitter:
• Shell Tellus 22
• Mobil DTE 11
• Aral Vitam GF 22 or
• BP Energol HLP-HM 2
Hydraulic oils are toxic and must not be released into the environment!
Follow the manufacturer's instructions and contact your local authorities for
information on proper disposal.
ZIPPER MASCHINEN GmbH
www.Zipper-Maschinen.at
CLEANING, MAINTENANCE, STORAGE, DISPOSAL
NOTICE
NOTICE
After each use
After each oil change or every 8 operating hours
1 x per year
NOTICE
If the oil level is too low, the oil pump can be damaged,
whereas overfilling can lead to overheating of the
hydraulic system. Therefore check the oil level regularly
with the dipstick - see picture on the left!
NOTICE