Herunterladen Inhalt Inhalt Diese Seite drucken

Transportation And Storage; Technical Data - GreenWorks GD24X2AB Bedienungshandbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 8
NOTE
Wait until the engine stops after you stop the machine.
4.3
OPERATION TIPS
Blow around the outer edge of the unwanted materials to
prevent the unwanted materials from scattering.
Use rakes and brooms to clear the unwanted material
before you blow.
Make the surfaces wet before you clear the unwanted
material in dusty conditions.
Look out for children, pets, open windows, and cleaned
cars during operation.
Clean the machine.
Discard the unwanted material when you complete work.
5
MAINTENANCE
CAUTION
Do not let brake fluids, gasoline, petroleum-based materials
touch the plastic parts. Chemicals can cause damage to the
plastic, and make the plastic unserviceable.
CAUTION
Do not use strong solvents or detergents on the plastic
housing or components.
WARNING
Remove the battery pack from the machine before
maintenance.
5.1
CLEAN THE MACHINE
CAUTION
The machine must be dry. Humidity can cause risks of
electrical shocks.
Clear the unwanted material out of the air vent with a
vacuum cleaner.
Do not spray the air vent or put the air vent in solvents.
Clean the housing and the plastic components with a
moist and soft cloth.
6
TRANSPORTATION AND
STORAGE
WARNING
Remove the battery pack from the machine before

transportation and storage.

6.1
MOVE THE MACHINE
Only hold the machine with the handgrip.
English
6.2
STORE THE MACHINE
Clean the machine before storage.
Make sure that the motor is not hot when you store the
machine.
Make sure that the machine does not have loose or
damaged parts. If it is necessary, do these steps/
instructions:
Replace the damaged parts.
Tighten the bolts.
Speak to a person of an approved service center.
Store the machine in a dry area.
Make sure that children cannot come near the machine.
7
TROUBLESHOOTING
PROBLEM
The motor does
not start when
you pull the trig-
ger.
The machine does
not start.
The air does not
flow through the
tube when you
start the machine.
8

TECHNICAL DATA

Voltage
Air volume
Air speed
Weight (without battery pack)
Measured sound pressure level
Guaranteed sound power level
Vibration
5
POSSIBLE
SOLUTION
CAUSE
Make sure that
The battery packs
you tighlty install
are not installed
two battery packs
tightly.
in the machine.
The battery packs
Charge the battery
are out of power.
packs.
One of the battery
Charge the battery
packs is out of
pack.
power.
The power switch
is defective.
Replace the defec-
The motor is defec-
tive parts by an ap-
tive.
proved service
center.
The PCB board is
defective.
The air inlet or
Remove the block-
tube outlet has a
age.
blockage.
2X24 V DC
16.4 m³/min
217 km/h
2.3 kg
L
= 90 dB(A), K
PA
3 dB(A)
L
= 100 dB(A)
WA.d
2
< 2.5 m/s
2
m/s
EN
=
PA
, K = 1.5

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ble402

Inhaltsverzeichnis