Herunterladen Inhalt Inhalt Diese Seite drucken

REMEHA iSense Bedienungsanleitung Seite 75

Zeitschaltthermostat
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

Problem
Solution
Problem
Solution
The house is too warm.
Weather-compensated control means that no account is taken of the measured
room temperature. Solve the problem in one of the following ways:
- Set the radiator thermostat valves correctly.
- Reduce the heating curve (see the installation and service manual).
- Change the control strategy (see the installation and service manual).
Room control may mean that the heat up rate is too high or that the controller
is not correctly calibrated.
The house does not become warm enough.
Weather-compensated control means that no account is taken of the measured
room temperature. Solve the problem in one of the following ways:
- Set the radiator thermostat valves correctly.
- Increase the heating curve (see the installation and service manual).
- Change the control strategy (see the installation and service manual).
EN
T001021-06-A
T001022-06-A
75

Quicklinks ausblenden:

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Timer thermostat

Inhaltsverzeichnis