Herunterladen Inhalt Inhalt Diese Seite drucken

General Information; General Safety; Technical Data - BFT MAXIMA ULTRA 36 Installations- Und Gebrauchsanleitung

Automatische schranke
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

1.1 INTRODUCTION
Carefully read the handbook before installing and using the product, and before performing
routine or corrective maintenance.
The directions preceded by this symbol contain information of particular importance. Non-
compliance with such directions can result in the loss of the contractual warranty.
THE OPERATIONS THAT, IF CARRIED OUT INCORRECTLY, CAN POSE RISKS, ARE INDICATED WITH THE SYMBOLS:
The INSTALLATION USE AND MAINTENANCE handbook is intended for installers, users and maintenance
operators.
The Company is not liable for any damage caused to persons, animals or property caused by use of the
product exceeding the limits reported in the attached data sheet or not complying with the intended use.
ATTENTION! Follow all instructions. An incorrect installation can cause serious injury.

1.2 GENERAL SAFETY

• Dispose of the packaging materials (plastics, cardboard, polystyrene, etc.) as required by the standards in force.
Do not leave envelopes in nylon and polystyrene within the reach of children.
• Cut off the power supply before carrying out any work on the equipment. Also disconnect any buff er batteries if
present.
• Provide on the mains power supply of the automation a switch or an omnipolar thermal magnetic circuit breaker
with contact opening distance equal to or greater than 3.5 mm.
• Check that upstream of the power supply system there is a diff erential switch with 0.03A threshold.
• The outputs are not of type SELV (safety extra low voltage), therefore no reachable part is allowed.
• Apply all safety devices (photocells, sensitive edges, etc.) necessary to protect the area from crushing, conveying,
shearing hazards, according to and in compliance with the relevant directives and technical standards.
• The Company accepts no responsibility in terms of safety and good operation of the automation if components
from other manufacturers are used.
• Use only genuine parts for any maintenance or repair.
• Do not carry out any modifi cation to the components of the automation if not expressly authorized by the Com-
pany.
• Instruct the user of the system as regards the control systems applied and the execution of the manual opening
in the event of an emergency.
• Do not allow persons and children to stay in the operating area of the automation.
• Do not leave remote controls or other control devices within the reach of children to prevent accidental opera-
tion of the automation.
• Do not allow children to play with the equipment.
• The equipment can be used by children aged 8 years or over and by people with reduced physical, sensory or
mental capacities, or lacking experience or the necessary knowledge, provided they are supervised or after the
same have received instructions relating to the safe use of the equipment and to the understanding of the relevant
hazards.
• Cleaning and maintenance intended to be performed by the user must not be carried out by children without
supervision.
• Everything not expressly provided for in these instructions is not allowed.
1.3 OVERVIEW
The automatic electromechanic barrier was designed to manage openings whose maximum width is 6 meters.
It is the ideal solution for vehicle management.

1.4 TECHNICAL DATA

Power....................230Vac/115Vac ±10% 50/60 Hz
Motor...........................230Vac 910RPM 0.25 kW
........................................................370 W
Absorbed power
Control unit...............................................CSB-Xtreme
Safety to impact..............................................Encoder
Opening time.....................................0.7 ÷ 3.9 s **
Bar length.........................................................2 ÷ 6 m

1. General information

ELECTROCUTION
CRUSHING
Operating temp.............-40*** +60°C
Actuations over 24h
...........20.000 bar length up to 3 m
...........5.000 bar length up to 6 m
Protection class...............................IP 55
Net weight.........................................69 kg
Gross weight....................................72 kg
- 9 -
Sound pressure level at 1 mt.
...............................................................LpA≤70 dB (A)
** The opening times are evaluated starting
from bar in closed position at the beginning of
the slowdown, at ambient temperature.
*** With built-in heater ON
EN

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Maxima ultra 36xl

Inhaltsverzeichnis