Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

The air conditioner
is leaking.
Compressor does
not work.
The remote
control does
not work.
If problems not listed in the table occur or recommended solutions do not work, please contact the
service centre.

ERROR CODES

Fault Code
Fault Description
F1
Compressor IPM error
F2
PFC/IPM error
F3
Compressor start error
F4
Compressor running out of step
F5
Location detection loop failure
F6
PCB communication error
F8
Sensor on suction pipe error
FA
Phase current overcurrent protection
FL
Water-full protection
Over-heat protection on top of
P1
compressor
P2
Dc bus voltage Undervoltage protection
P3
AC Input voltage protection
P4
AC over-current protection
The unit is not straight.
The drain pipe is blocked.
Overheat protection operational.
The remote control is not aligned
with the direction of the remote-
control receiver.
Batteries poor.
Use a spirit level to check the unit is
horizontal, if not remove from the wall
and Straighten.
Check the drain pipe to ensure it is
not blocked or constricted.
Wait for 3 minutes until the
temperature is lowered, and then
restart the machine.
Let the remote control get close to
the air conditioner, and make sure
that the remote control directly faces
to the direction of the remote-control
receiver.
Replace batteries.
Fault Code
Fault Description
P5
AC undervoltage protection
P7
Defrost protection on coil tube
P8
Zero-crossing fault detection
Return air sensor temperature
PA
abnormal protection
PE
Abnormal refrigerant circulation
PH
Exhaust temperature protection
E0
Sensor on suction pipe error
E1
Temperature sensor error
E2
Sensor error on indoor coil tube
E3
DC fan Feedback failure
E5
Water-splash motor error
E8
Fan feedback fault
EE
EE error