The appliance must be installed in a room without sources of
ignition (for example: open flames, an operating gas appliance
or an operating electric heater).
The unit must be installed on a solid vertical wall by a
competent person. The electricity supply must only be
connected after installation is complete.
R290 refrigerant gas complies with European environmental
directives.
R290 has a low GWP (Global Warming Potential) of 3.
The air conditioner contains about 290 g of R290
refrigerant gas.
Do not install or store in an unventilated space with an area
smaller than 15 m2 per unit. The room must be such as to
prevent stagnation of possible leaks of refrigerant gas as there
could be a danger of fire or explosion hazard should the
refrigerant come into contact with electric heaters, stoves or
other sources of ignition.
If the appliance is installed, used or stored in an unventilated
room, the room must be such as to prevent stagnation of
possible leaks of refrigerant gas as there could be a danger of
fire or explosion should the refrigerant come into contact with
electric heaters, stoves or other sources of ignition.
Refrigerant gas may be odourless.
Do not use the product and contact the retailer for advice,
if damage has occurred to the unit which may have
compromised the refrigerant system.