• Do not obstruct or cover ventilation openings.
• Always disconnect the product from the power outlet when
cleaning or moving the product.
• Do not pull the power cable to move the product.
• Unplug the product from the power source and other equipment
if problems occur.
• Switch off the main power switch before unplugging the power
cord.
• Do not use the product when the cord or plug is damaged.
• Do not unplug the product by pulling on the cable. Always grasp
the plug and pull.
• Make sure that the electrical supply in your area matches a
voltage of 220 – 240 VAC and a frequency of 50 Hz.
• Connect to a grounded socket only.
• If necessary, use an earthed extension cable of a suitable
diameter.
• Fully extend the power cord and make sure the power cord does
not contact the product.
• When using an extension cord, use one which is as short as
possible and fully extended.
• Do not use external timers or remote control systems to switch
the product on or off.
• Ensure people do not trip over the cord.
• Do not leave the product unattended when switched on.
• R290 is a refrigerant gas that complies with the European
directives on the environment.
• Be aware that refrigerants can be odorless.
• Place the product in an area without any continuous sources of
ignition (for example: open flames, gas or electrical appliances in
operation).
• Keep the product at a distance from flammable objects such as
furniture, curtains and similar.
• Only install, operate and store the product in a room with a floor
area above 9 m
.
2
• Only use the provided exhaust hose.
• Do not block the exhaust hose. Blocking the exhaust hose may
cause overheating.
• Do not twist the exhaust hose.
• Ensure that the exhaust hose does not kink.
• Only store the product in a well-ventilated area.
• When the product is installed, operated or stored in a
non-ventilated area, make sure the room is designed to prevent
the accumulation of refrigerant leaks resulting in a risk of fire or
explosion due to ignition of the refrigerant caused by electric
heaters, stoves, or other sources of ignition.
• Only persons with a current valid certificate from an
industry-accredited assessment authority, which authorizes their
competence to handle refrigerants safely in accordance with an
industry recognized assessment specification, can work on or
break into a refrigerant circuit.
• Servicing can only be performed as recommended by the
equipment manufacturer. Maintenance and repair requiring the
assistance of other skilled personnel can only be carried out
under the supervision of the person competent in the use of
flammable refrigerants.
• When defrosting and cleaning the product, do not use any
means other than those recommended by the manufacturing
company.
• Do not puncture or heat any part of the refrigerant circuit.

Installing the product

Place the product on a stable and flat surface.
4
Only move the product in an upright position.
4
Leave a minimum of 0.5 m free space around the air outlet and
4
swing louvers to allow a good circulation of airflow.
If the product has been tilted, allow it to stand upright for 2 hours
4
before plugging it in.
Keep the product at a distance from flammable objects such as
4
furniture, curtains and similar.
Do not block ventilation openings and make sure that there is
4
enough space around the product.
Only install, operate and store the product in a room with a floor
4
area above 9 m
.
2
1. Plug the power cable A
Assembling the exhaust (image C)
Only use the provided exhaust hose.
4
Do not block the exhaust hose. Blocking the exhaust hose may
4
cause overheating.
1. Assemble the exhaust hose A
the exhaust hose connector A
2. Slide A
over the air outlet A
e
3. Extend A
5
up to 1500 mm.
Do not twist the exhaust hose.
4
Ensure that the exhaust hose does not kink.
4
4. Assemble the window kit A
A
7
.
5. Install A
6
in the window opening.
6. Tighten A
.
7
7. Snap A
into A
4
6
and fasten with the exhaust nozzle screw
A
t
.
Assembling the continuous drainage (optional)
1. Open the drainage outlet A
2. Connect A
q
to a water container or drainage system (not
included).
Placing the batteries in the remote control
1. Slide the battery cover off the back of the remote control A
2. Insert 2 type AAA batteries.
3. Slide the battery cover back in place on A
Installing the Nedis SmartLife app
1. Download the Nedis Smartlife app for Android or iOS on your
phone via Google Play or the Apple App Store.
2. Open the Nedis Smartlife app on your phone.
3. Create an account with your mobile phone number or your
e-mail address and tap Continue.
You will receive a verification code on your mobile phone or
4
e-mail address.
4. Enter the received verification code.
5. Create a password and tap Done.
6. Tap Add Home to create a SmartLife Home.
7. Set your location, choose the rooms you want to connect with
and tap Done.
Adding a product to the Nedis SmartLife app
1. Switch on the product.
2. Tap + in the Nedis SmartLife app.
3. Select the device type you want to add from the list.
4. Confirm the Wi-FI indicator LED B
If B
is not blinking fast, press the Speed button B
4
3
product for 5 seconds during standby mode to reset the product.
5. Follow the instructions in the Nedis SmartLife app.
6. Rename the product after it has been found and added.
7. After confirming you can control the product with your
smartphone.
To connect your SmartLife account to Amazon Alexa and/ or Google
Home, set it up using the "Smart Life" action or skill. For more details
check the instruction on either Amazon or Google.
5
w
into the power outlet.
, the exhaust nozzle A
5
e
.
.
9
6
with the window kit fasteners
q
.
r
.
3
is blinking fast.
5
4
and
r
on the

Werbung