Fig. 14
INSTALLING THE DUCTING VERSION
6. Fitting the telescopic flues:
- Adjust the width of the telescopic flue support bracket (D) using the screws F indicated in Fig. 8.
- Then, using the screw anchors and the screws (G) provided, fit the bracket to the ceiling in such a way that it is in line with
the hood (Fig. 8).
- Fit the 2 glass stops to the sides of the lower flue: screw in the screw working from the inside of the lower flue an lock the
glass stop (Fig. 10).
- Connect the air exhaust pipe to the air vent using a metal clamp (pipe and clamps not provided).
- Make the electrical connection of the hood by means of the power cable.
- Fit the telescopic flues resting them on the hood; raise the upper flue as far as the ceiling and secure it with the 2 screws
H (Fig.12).
- Secure the lower flue with 4 screws, working from the inside of the hood (Fig. 13).
- In the ducting version, the charcoal filter is not required; therefore if it has been installed, remove it by pushing the catch inwards
and turning the filter downwards until the 2 clips slip out of their seats (Fig. 14).
7. Fitting the grease drip trays: position the 2 drip trays inside the hood in proximity of the halogen lamps and move the trays
sideways towards the outside of the hood (Fig. 15).
8. Fitting the glass panel: Fit the 2 plastic strips on the upper edge of the glass panel (Fig. 16); Position the glass panel in the
2 glass stops and secure it to the hood with 2 screws and 4 washers (Fig. 16).
Technical data
-
1 Motor power 370 W
-
Voltage: 230-240V single phase
-
3 halogen lamps 20W
-
Supplied with 150 cm electricity supply cable with plug.
-
Gross weight : Kg. 39.5
-
Net weight : Kg. 34.5
-
2 metallic grease filters
Dimensions (Fig. 17)
Fig. 15