Herunterladen Inhalt Inhalt Diese Seite drucken

Gude GGH 10 INOX Originalbetriebsanleitung Seite 20

Gasheizgebläse
Vorschau ausblenden Andere Handbücher für GGH 10 INOX:
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

ENGLISH
Power requirement of pilot flame
Power requirement of pilot flame(if present)
Thermal efficiency (NCV)
At rated heat output
At minimum heat output (Reference value)
Type of heat output/room temperature control (select one)
Single-stage heat output without room temperature control 
Two or more manual stages without room temperature control 
With room temperature control using mechanical thermostat 
With electronic room temperature control 
Electronic room temperature control with daily timer 
Electronic room temperature control with weekly timer
Other control options (multiple selection possible)
Room temperature control using presence detection 
Room temperature control using open window detection
With remote control option 
With adaptive switch-on control 
With operating time limit 
With "Black Bulb" temperature sensor, black 
Space heating annual efficiency 
Energy Efficiency Index 
Energy Efficiency Class 
(*)NOX= Nitric oxides
Read and understand the operating
instructions before using the appliance.
In case of any doubts about connection
and operation refer please to our customer center
The product is designed for use by
persons aged 16 or older.
This appliance is not intended for
use by persons (including children)
with reduced physical, sensory
or mental capabilities, or lack of
experience and knowledge, unless
they have been given supervision
or instruction concerning use of the
appliance by a person responsible
for their safety. Children should be
supervised to ensure that they do
not play with the appliance.
20
P
pilot
η
th, nom
η
th, min
Specified Conditions of Use
This product is only suitable for occasional use.
The gas fan heater is designed for heating, drying
buildings and de-icing and must only be operated in
well-ventilated rooms or outdoors.
Ventilation openings of at least 250 cm
INOX appliance and 425 cm
ance (at least 25 cm
per 1 kW nominal heat output) must
2
be provided in the installation rooms.
The minimum room size must not be less than 100 m
the GGH 10 INOX appliance and 170 m
INOX appliance (1 m
per 100 W nominal heat output).
3
When using the device, the respective local building and
fire protection regulations must be observed.
Please note that our equipment has not been designed
for commercial, craft or industrial use. If the equipment
is used in commercial, craft or industrial operation or for
similar activities, we cannot assume any liability.
Do not use this product in any other way as stated for
normal use. Not observing general regulations in force
and instructions from this manual does not make the
manufacturer liable for damages.