Herunterladen Inhalt Inhalt Diese Seite drucken

Reset; Technical Data; General Declaration Of Conformity; Troubleshooting - Selve Lineco-Serie Originalbetriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

Reset/Technical data

5. Reset

Power the black and brown connection wires simultaneously for approx. 3 seconds.
The motor acknowledges the reset with a short up­down movement. The delivery
status is restored.

6. Technical data

Series
Lineco 7
Lineco 10
Lineco 15
Information for all motor types:
Nominal voltage: 230 V AC/50 Hz
Safety class:
IP 44
Operating time:
4 Min.
Subject to change without prior notice!

7. General declaration of conformity

SELVE GmbH & CO. KG company, hereby declares that the Lineco is in conformity with
the basic requirements and other relevant provisions of the Directive 2006/42/EG,
2014/30/EU and 2011/65/EU.

8. Troubleshooting

Problem
Motor does not work
UP and DOWN directions are
switched
Motor has stopped automatically
when moving DOWN and releases
Motor has stopped automatically
when moving UP and releases
Torque
Rotation speed
Nm
Rpm
7
17
10
17
15
17
Cause
Electric connection defective
Thermal protection switch has
triggered
Black and brown wire connected to
the switch incorrectly
Blockage/obstacle recognition has
triggered
Overload recognition has triggered
21
Power Input
Output
A
0.41
0.45
0.66
Solution
Check the connection
Wait for 5 to 20 minutes
Switch wires
(black = rotation right,
brown = rotation left)
Remove obstacle, check curtain
path
Remove obstacle, check curtain
path, possibly select stronger motor
EN
W
95
105
152
EN

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Diese Anleitung auch für:

Lineco 7Lineco 10Lineco 15

Inhaltsverzeichnis