For the heat pump to operate normally, the ambient air temperature must be
between -5°C and 43°C.
MV-1058-1059-10-2021 . swim-fun.com © All rights reserved Swim & Fun A/S
124
Ambient temperature for enabling auxiliary
electric heating
Temperature compensation value
Coil temperature for starting defrosting
Coil temperature for exiting defrosting
Ambient temperature to allow defrosting
The set difference between the ambient
temperature and the coil temperature for
starting defrosting
The over heating temperature of differen-
ce between ambient temperature and coil
temperature at which defrosting is started in
advance
Compressor operation cycle of entering the
defrosting
Defrosting running time, 0 is to cancel the
defrosting function
Main valve regulating cycle
Minimum opening of main valve when
cooling
Minimum opening of main valve when
heating
Extended parameter - The serial number of
the parameter
Extended parameters - The set data
-50~30
°C
-10~10
°C
-30~15
°C
0~40
°C
-30~30
°C
0~20
°C
0~20
°C
1~240
Min
0~99
Min
10~120
Sec
0~480
P
0~480
P
0~9999
0~9999