Electrical safety

The electric motor has been designed for one
voltage only. Always check that the power supply
corresponds to the voltage on the rating plate.
This tool must be connected to an
earthed mains outlet.
Mains plug replacement
(U.K. & Ireland only)
• Should your mains plug need replacing and you
are competent to do this, proceed as instructed
below. If you are in doubt, contact an authorized
D
WALT repair agent or a qualified electrician.
E
• Disconnect the plug from the supply.
• Cut off the plug and dispose of it safely; a plug
with bared copper conductors is dangerous if
engaged in a live socket outlet.
• Only fit 13 Amperes BS1363A approved plugs
fitted with the correctly rated fuse (1).
• The cable wire colours, or a letter, will be marked
at the connection points of most good quality
plugs. Attach the wires to their respective points
in the plug (see below). Brown is for Live (L) (2),
blue is for Neutral (N) (4) and green/yellow is for
Earth (E).
• Before replacing the top cover of the mains plug
ensure that the cable restraint (3) is holding the
outer sheath of the cable firmly and that the two
leads are correctly fixed at the terminal screws.
Never use a light socket.
Never connect the live (L) or neutral (N)
wires to the earth pin marked E or
For 115 V units with a power rating exceeding 1500 W,
we recommend to fit a plug to BS4343 standard.
17

Using an extension cable

If an extension cable is required, use an approved
3-core extension cable suitable for the power input of
this tool (see technical data).
The minimum conductor size is 1.5 mm
When using a cable reel, always unwind the cable
completely. Also refer to the table below.
Conductor size (mm
0.75
1.00
1.50
2.50
4.00
Voltage
Amperes
115
0 - 2.0
2.1 - 3.4
3.5 - 5.0
5.1 - 7.0
7.1 - 12.0
12.1 - 20.0
230
0 - 2.0
2.1 - 3.4
3.5 - 5.0
5.1 - 7.0
7.1 - 12.0
12.1 - 20.0

Assembly and adjustment

Prior to assembly and adjustment always
unplug the tool.
Setting the air temperature (fig. B)
The air temperature can be adjusted to suit a wide
range of applications. The table below suggests
settings for different applications.
Setting
.
Low (1st sector)
E N G L I S H
2
.
2
)
Cable rating (Amperes)
6
10
15
20
25
Cable length (m)
7.5
15
25
30
Cable rating (Amperes)
6
6
6
6
6
6
6
6
10
15
10
10
15
20
15
15
20
25
20
20
25
6
6
6
6
6
6
6
6
6
10
10
10
10
15
15
15
15
20
20
20
20
Applications
• Drying paint and varnish
• Removing stickers
• Waxing and dewaxing
• Drying wet timber prior to filling
• Shrinking PVC wrapping and insulation tubes
• Thawing frozen pipes
45
60
6
6
10
6
15
15
20
20
20
25
25
-
-
-
-
6
6
6
6
6
6
6
10
15
15
15
20
20
25
-
en - 4