QUICK START GUIDE

BATTERY INSTALLATION AND BATTERY TYPESETTING (WET OR GEL/ AGM)

According to the type of batteries (WET or GEL/AGM), set the machine and electronic board of the battery charger
as follows: (only for disc machine)
WET BATTERIES
1
(NOTE: Turn the DIP switch 1
and 2 both to "OFF". )
DISCOVER EV AGM
2
BATTERIES
(NOTE: Turn the DIP switch 1
to "ON" ; 2 to "OFF" .)
GENERAL GEL/AGM
3
BATTERIES
(NOTE: Turn the DIP switch 1
and 2 both to "ON" .)
NOTE
When install new batteries please refer to Figure 4 to adjust the DIP switches. Otherwise the bat-
teries may be damaged.
Machine setting (only for disc machine)
Turn the ignition key (35) to "I" and in the very first seconds of machine operation pay attention to the following:
1.
If the first green warning light (38) is flashing, the machine is set to GEL/AGM.
If the yellow warning light (37) is flashing, the machine is set to Discover EV AGM.
If the red warning light (36) is flashing, the machine is set to WET.
If the setting need to be changed, perform the
following procedure.
2.
The factory setting is for WET batteries.
If the setting correspond to the battery installation, go
to step6 directly. Otherwise, follow next steps 4~5.
3.
Remove the screws on control panel (C, Figure 4),
then turn over the PCB (A Figure 4) to find the DIP
switch (B, Figure 4) for setting battery type (WET or
Discover EV AGM or GEL/AGM), (Refer to 1 or 2
or 3).
4.
If the setting complete to the battery option. Install
the screws on control panel.
Battery charging (only for disc machine)
5.
Charge the batteries. (See procedures in maintenance
chapter).
CAUTION!
Cut off all the power of the machine be-
fore perform the following procedure!
B
C
D
Figure 4
A
B
C
E
D
Figure 4.1
9
ENGLISH
A
SW1
ON
OFF
DP1 DP2
DP1 DP2 CHARGING CURVE
ON
OFF IUIa Wet
OFF
OFF IUIa Gel EXIDE
OFF
ON
IUoU AGM
ON
ON
IUIUo AGM Discover