Full calibration for object recognition
If the object is too close to the sensor, the
calibration is canceled with an error. See
during
calibration.

Calibration for fill level detection

SmartLEVEL sensors can be typically be used
with the factory settings.
Calibration is only necessary in exceptional cases.
During a full calibration, the fill level should cover
about 50% of the active surface.
Full calibration for fill level detection
For a secure switch-off in applications with
adhesive build-up or foaming, an empty
calibration increases the performance. First run a
fill and empty sequence to get an application
typical build-up. Subsequently perform an empty
calibration.
Empty calibration with build-up

Calibration for leakage application

Perform empty calibration after installation.
www.balluff.com

Operation with IO-Link

With IO-Link devices, you can change the behavior
via additional parameters (see section IO-Link).
These parameters are also effective in SIO mode.

Switching output in SIO mode

If no master is connected to IO-Link devices, they
automatically use the SIO mode, i.e. the device
functions as a sensor with a conventional
switching power amplifier. Via the
Display
Mode"
configured as PNP, NPN or PushPull. The switching
output can be set as either N.C. or N.O. via the
"Switch Point Mode.Logic"

Adjustable hysteresis

The difference between the switching point and
reset point is called hysteresis and can be set via
the
"Switch Point Mode.Hysteresis"
corresponds to minimum and 10 to maximum
hysteresis.

Adjustable delay

To suppress short switch-on pulses, the switch
signal activation can be extended via the
"Delay.On"
influence switching off.
Accordingly, the switch signal deactivation can be
extended via the

Adjustable filter

The switch signal can be delayed using the
"Delay.Filter"
switch signal changes will be delayed by the filter
time. Any switching impulses that are shorter than
the filter time are masked.

Maintenance

The device is maintenance-free. If necessary,
contaminations on the device can be removed
using a nonaggressive cleaner.

Disposal

Repairs to the device are not possible.