Troubleshooting
Handling the machine with the power supply up can lead to serious injuries or even
death. Always disconnect the machine from the power supply before servicing or
maintenance work and secure it against unintentional or unauthorised reconnection!
Many possible sources of error can be excluded in advance if the machine is properly connected
to the mains. If you are unable to carry out necessary repairs properly and/or do not have the
required training, always consult a specialist to correct the problem!
Trouble
Machine does not start
No/too slow spindle rotation
Squeaking noise when
machine is switch on
Machine vibrates
Workpiece shows burn traces
Bad cutting surface
HOLZMANN MASCHINEN GmbH
W A R N I N G
Possible cause
switch or a phase is broken
Fuse activate
Open door for V-Belt access
V-Belt tension too low or
cracked V-Belt
V-Belt tension too low
Damages tools
Machine not levelled
Cutting depth too high
Feeding speed too high
blunt tool
dirt or pitch on cutter
feeding work in the wrong
direction
www.holzmann-maschinen.at
TROUBLESHOOTING
Solution
Repair the defective circuit or
the faulty phase
Replace/check the fuse
Close the door
Tensioning / replace V-Belt
Tensioning V-Belt
Replace tool
Level machine
produce the desired depth in
several steps
reduce feeding speed
replace tool
clean tool
feed work against the cutter
rotation (right to left)
FS160SOLID
39