Modbus
Register
adress
30044
S_YEAR_ALARM_1
30045
S_MONTH_ALARM_1
30046
S_DAY_ALARM_1
30047
S_HOUR_ALARM_1
30048
S_MINUTES_ALARM_1
30049
S_SECONDS_ALARM_1
DE
30050
S_ALARM_2
30051
S_YEAR_ALARM_2
30052
S_MONTH_ALARM_2
30053
S_DAY_ALARM_2
30054
S_HOUR_ALARM_2
30055
S_MINUTES_ALARM_2
30056
S_SECONDS_ALARM_2
HOLDING REGISTERS (READ/WRITE)
Modbus
Register
adress
Modbus configuration
40001
Adress
40002
Baud rate
40003
Parity
Resets
40004
Factory_Reset
40005
Reset_Alarms_Count
40006
Full_Reset
General configuration
40009
Vreg_Limit_min
40010
Vreg_Limit_max
40011
Taco_pulses_out
40012
Vreg_BOOST
40013
NIGHT_REDUCTION
40014
BOOST_TIMER
40017
SLAVE_ENABLE
40018
SLAVE_OFFSET
16
Data type
Range
16 BITS
18 – 999
16 BITS
1 – 12
16 BITS
1 – 31
16 BITS
0 – 23
16 BITS
0 – 59
16 BITS
0 – 59
16 BITS
0 – 1
16 BITS
18 – 999
16 BITS
1 – 12
16 BITS
1 – 31
16 BITS
0 – 23
16 BITS
0 – 59
16 BITS
0 – 59
Data
Range
type
CRHB/CRVB N
CRHT/CRVT N
ECOWATT PLUS
16 BITS
1 – 247
16 BITS
0 – 3
16 BITS
0 – 2
16 BITS
0 – 65535
16 BITS
0 – 65535
16 BITS
0 – 65535
16 BITS
0 – 10000
16 BITS
0 – 10000
16 BITS
0 – 10
16 BITS
0 – 10000
16 BITS
0 – 100
16 BITS
0 – 600
16 BITS
0 – 1
16 BITS
-50 – 50
Description
Year of last IAQ alarm
Month of last IAQ alarm
Day of last IAQ alarm
Hour of last IAQ alarm
Minute of last IAQ alarm
Second of last IAQ alarm
Second to last IAQ alarm:
0: No alarm
1: AN1 IAQ alarm
2: AN2 IAQ alarm
3: AN3 IAQ alarm
Year of second to last IAQ alarm
Month of second to last IAQ alarm
Day of second to last IAQ alarm
Hour of second to last IAQ alarm
Minute of second to last IAQ alarm
Second of second to last IAQ alarm
Default
Description
1
Modbus channel
Transmission speed
0: 4800bps
2
1: 9600bps
2: 19200bps
3: 38400bps
Transmission parity
0: EVEN
0
1: ODD
2: NONE
If parity NONE, 2 bits stop as default. If not, 1 bit stop
Back to factory settings
0
1234: Reset factory settings
Alarm count reset independently
0
2345: Motor alarm count
2456: IAQ alarm count
To reset all
0
3456: Full reset
1500
Minimum 0-10 voltage tension to the motor (mV)
10000
Maximum 0-10 voltage tension to the motor (mV)
1
Pulses by motor revolution
10000
Voltage in mV when Boost activated
% that will decrease the motor control voltage (VAV
50
mode) or setpoint (COP and CAV modes)
Time in minutes that boost will be activated once
0
disconnected
Slave function:
1
0: OFF
1: ON
Offset applied to slave in comparison with master
0
setpoint. Take into account control limits defined by
40009 and 40010