Maintenance and care
Installing the recirculating ball bearing
84
02.00 | MLD-L | Montage- und Betriebsanleitung | en | GAS364815
Installing the recirculating ball bearing
Mount the two recirculating ball bearings (1) onto the locating
Ø
bearing side of the guided slide. Tighten the screws only to
some extent (2).
Place the guided slide (3) onto the guide (4) and push the two
Ø
recirculating ball bearings (5) under the guided slide from the
side.
Tighten the screws to some extent (2).
Ø
Screw in the assembly tool (8) to pre-load the recirculating ball
Ø
bearing to 300N, while carefully moving the guided slide back
and forth by hand.
Tighten screws (2) to 5.6 Nm using the torque wrench
Ø
Mount the screws (6) and lock in place with screw locking liquid.
Ø
Take out the assembly tool, screw in the screws (7) and lock in
Ø
place with locking liquid.
Installing the motor housing
Ø
If necessary, readjust the measuring system
Ø
measuring system
Changing the motor housing
[
}