Herunterladen Inhalt Inhalt Diese Seite drucken

Installation Instructions - COMFORTPOOL Inverter Pro Benutzer- Und Wartungshandbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

2. Installation instructions

WARNING
Consult your dealer for installing the heat pump. It should not be installed by the user since
installation requires specialized knowledge and skills. An improperly installed heat pump may
cause water leakage, fire, or electric shock.
Provide a dedicated power supply for the heat pump. A non-dedicated power supply may cause
overheating or fire.
Do not install the unit where flammable gas could leak. If gas leaks and accumulates around the
unit, it may cause an explosion.
Ground the unit correctly. Do not connect the ground wire to a gas pipe, water pipe, lightning
rod, or a telephone ground wire. Improper earthing may cause electric shock.
CAUTION
Install a RCD depending on the installation location of the heat pump (such as highly humid
areas).If a RCD is not installed, it may cause electric shock.
Ensure that the drain water is properly drained. If the drain passage is improper, water may drip
down from the unit, wetting and damaging the furniture.
Please prepare the professional tools for R32 refrigerant heat pump before you do maintenance.
The factory only provides the heat pump unit. Other items, including an eventual bypass, that are necessary for
the water system, are to be provided by users or installers.
Attention! Please follow these steps when installing the heat pump:
1. All feeding of chemicals to the pool water must be done downstream of the heat pump.
2. Install a bypass when the flow of the pool pump is more than 20% above the rated flow of the heat
exchanger of the heat pump.
3. Install the heat pump on a solid foundation and use the damping rubbers to eliminate vibrations and
noise.
4. Always keep the unit straight up. If the unit has been tilted or put on its side, allow 24h before starting
the unit.
R32
leak
detector
Explosion-
Antistatic
proof
vacuum
gloves
pump
28