Pin 3
End position
White (WH)
contact
„Retracted"
Pin 4
Green (GN)
Pin 5
End position
Pink (PK)
contact
„Extended"
Pin 6
Yellow (YE)
Pin 7
Not connected
Black (BK)
Leave unconnected
Pin 8
Grey (GY)
Pin 9
Red (RD)
Continued from previous page
End position contact
The linear drive has two potential-free, mechanical switches (NO = normal open / normally
open). On each end position one switch is closed. The contacts can be used, for example,
to control relays, signal lamps, etc. pp.
Specification
potential-free switch (NO)
= 0 ... 30V
U
= 0 ... 100mA
I
Example
In the example, two signal lamps are connected to visualize the end positions. The L1 sig-
nal lamp lights up when the linear drive is retracted. The L2 signal lamp lights up when the
linear drive is extended.
Signal lamp
Signal lamp
extended
retracted
L1
L2
F1
-
+
Continued on next page
BN
BU
WH
WH
GN
PK
YE
BK
GY
RD
Fuse
Battery