Example H
+
R
9 V
+
Sensor 1
Sensor 2
Description: 4 different sensors are connected to the 4 pins of a single device port and together via
Ground. The required 12 V power for Sensor 2 and Sensor 4 is supplied together from ORION, while
power is supplied separately and individually to the other sensors. To Pin 1 and Pin 2 each, an NPN
output sensor with an open collector is connected plus a 1k Ω – 10k Ω resistor. DC 12 V power is
supplied to ORION.
Example I
R
9 V
+
Sensor 1
Sensor 2
Description: 4 different sensors are connected to the 4 pins of a single device port and together via
Ground. The required 9 V power for Sensor 1 is supplied from ORION. The required 5 V power for
Sensor 3 is supplied separately and individually. Sensor 2 and Sensor 4 are supplied 24 V power
separately, but together from one power source. To Pin 1 and Pin 2 each, an NPN output sensor with
an open collector is connected plus a 1k Ω – 10k Ω resistor. DC 9 V power is supplied to ORION.
11
11
EN
EN
+
R
12 V
+
+
Sensor 3
+
R
24 V
+
+
Sensor 3
5 V
12 V
+
Sensor 4
+
5 V
24 V
+
Sensor 4