Example E
+
R
9 V
+
Sensor 1
Sensor 2
Description: 4 different sensors, each with their own supply of power, are connected to the 4 pins
of a single device port. All are connected to ORION together via Ground. To Pin 1 and Pin 2 each, an
NPN output sensor with an open collector is connected plus a 1k Ω – 10k Ω resistor. Power to ORION
is supplied separately with DC 5 V – 24 V or 5 V USB.
Example F
+
R
9 V
+
Sensor 1
Sensor 2
Description: 4 different sensors are connected to the 4 pins of a single device port and together via
Ground. The required 24 V power for Sensor 4 is supplied from ORION, while power is supplied
separately and individually to the other sensors. To Pin 1 and Pin 2 each, an NPN output sensor with
an open collector is connected plus a 1k Ω – 10k Ω resistor. DC 24 V power is supplied to ORION.
Example G
+
R
9 V
+
Sensor 1
Sensor 2
Description: 4 different sensors are connected to the 4 pins of a single device port and together via
Ground. The required 12 V power for Sensor 2 is supplied from ORION, while power is supplied
separately and individually to the other sensors. To Pin 1 and Pin 2 each, an NPN output sensor with
an open collector is connected plus a 1k Ω – 10k Ω resistor. DC 12 V power is supplied to ORION.
+
+
R
12 V
5 V
+
+
Sensor 3
+
+
R
12 V
5 V
+
+
Sensor 3
+
R
12 V
5 V
+
+
Sensor 3
+
24 V
+
Sensor 4
24 V
+
Sensor 4
+
24 V
+
Sensor 4