Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Specifications - MADRIX STELLA Kurzanleitung & Technisches Handbuch

Vorschau ausblenden Andere Handbücher für STELLA:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

End-Of-Life
This electrical device and its accessories need to be disposed of
properly. Do not throw the device into normal trash or household
waste. Please recycle packaging material whenever possible.
Usage
In general, this device is designed to be operated as a hardware control interface
to be connected towards various types of controllable lights / lighting controllers
via DMX512 by using USB or Art-Net / Streaming ACN over Ethernet.
Do not use the interface for any other, deviating purpose.
The device can be connected to and disconnected from USB or Ethernet network
during use and without a reboot (Hot Swapping & Plug and Play). Multiple
interfaces can be used at the same time.

Technical Specifications

Supply Of Power:
Power Consumption:
Network Protocols:
RDM Role:
DMX512:
Ports:
Ethernet:
Ethernet Switch:
USB:
Handling:
Case:
Dimensions:
Weight:
Temperature Range:
Relative Humidity:
IP Rating:
Certificates:
Warranty:
DC 5 V – 24 V; over
A) 2-pin, pluggable screw terminal or B) 5 V USB
< 1.5 W
during normal operation
(300 mA)
Art-Net
(I, II, 3, 4, incl. ArtSync)
Transmits commands and requests to RDM Responders and
back
(Art-Net Node / RDM Controller)
2x 512 DMX channels, input and/or output
2x ports
(Via 2x 3-pin, pluggable screw terminals)
2x RJ45, Auto MDI-X, daisy-chain support, 10/100 MBit/s
(Compatible with 1 GBit/s)
Lookup Table
for 1024 unicast MAC addresses
(ALU)
1x port, USB 2.0, type-B female socket
5 status LEDs
(+4 network status LEDs)
Non-conductive, V-0 flammability rating
designed for 35 mm DIN-rails or wall mounting
90 mm x 70 mm x 46 mm
108 g | 125 g incl. screw terminals and wall mounts
-10 °C to 70 °C
(Operating)
5 % to 80 %, non-condensing
IP20
CE, EAC, FCC, RoHS
5 years of limited manufacturer's warranty
(500 mA max. fused)
, Streaming ACN
(sACN / ANSI E1.31)
(Automatically per port)
(UL94 test method)
(Length x Width x Height)
| -20 °C to 85 °C
(Storage)
(Operating / Storage)
,
4
EN

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis