8. Maintenance

8.1. Updating a Bloom Lab

EN
The Bloom App informs you about any existing updates and
guides you through installation.

8.2. Setting up an administrator for a Bloom Lab

The fi rst Bloom App connected with the Bloom Lab is defi ned
as the administrator device. This device is also allowed to
rename the Bloom Lab to give it a unique identifi er.

8.3. Changing the administrator of a Bloom Lab

To reset the Bloom Lab, please press the reset button on the
back side of the Bloom Lab with e.g. a paper clip for more
than 5 seconds (Visual "Reset button on the Bloom Lab"). A
visual feedback can afterwards be seen on the LED ring.
Reset button on the Bloom Lab
After resetting the device, the fi rst Bloom App to be connect-
ed to it is defi ned as the administrator device.

9. Storage and transport

In order to avoid hazardous situations, the Bloom Lab should
be stored with care at all times, this includes:
• The recommended storage temperature of the Bloom Lab
is between -20°C and +60°C. Please store the Bloom Lab in
a dry place, away from direct or excessive heat. Make sure
to store the Bloom Lab in an environment with humidity
between 30 and 85%.
• The Bloom Lab should not be stored outside: it is intended
for indoor use only.
• The Bloom Lab should not be stored in: brightly sunlit,
moist, dirty, dusty, physically unstable, compressed, or
humid areas, or areas that experience rapid temperature
changes, areas that have strong magnetic fi elds (e.g. creat-
ed by multiple mobile phones, batteries, magnets, high volt-
age power transmitters, radioactive materials, microwaves,
TVs), or areas that experience strong power surges.
8

10. Disposal

Dispose of the Bloom Lab in accordance with your national
regulations regarding electronic waste. Please contact your
local authority to determine the proper method of disposal
of potentially biohazardous parts.
Before disposal or transportation the unit shall be cleaned and
disinfected. Use Braun Softa Cloth CHX 2% (Ref: 19581) or similar.
Do not dispose of the Bloom Lab as unsorted municipal
waste. Every person should reuse, recycle and recover
electronic waste responsibly to avoid hazardous substances
aff ecting health and the environment

11. LED indications and error handling

The Bloom Lab performs a self test during each start-up of
the device. Additional internal tests are performed during
each measurement to check for the correct function of the
device. The proper function of the Bloom Lab is indicated
via the LED indicator at the front of the device. See section
11.1. for more information. In case of malfunction, the user
is informed by the Bloom App and the LED indicator (Visual
"LED indications on the Bloom Lab").
LED indication ring
LED indications on the Bloom Lab

11.1. Proper function

The correct function and readiness of the Bloom Lab are
indicated by the LED ring. See Table N°1 for the meaning of
the various indications:
4-3-6-2 Bloom Lab IFU, 09.04.2020, V1.0