TECHNICAL DATA

DESCRIPTION
Heating
Heat input
Maximum heat output (80/60°C)
Minimum heat input
Minimum heat output (80/60°C)
DHW
Heat input
Maximum heat output
Minimum heat input
Minimum heat output
Useful efficiency (Pn max - Pn min)
Efficiency 30% (47°C return)
Combustion performance
Electric power
Pump electric power (1.000 l/h)
Category
Country of destination
Power supply voltage
Degree of Protection
Pressure drops on flue with burner on
Pressure drops on flue with burner off
Heating operation
Pressure - maximum temperature
Minimum pressure for standard operation
Selection field of heating water temperature
Pump: maximum head available
for system capacity
Membrane expansion tank
Expansion tank pre-charge
DHW operation
Maximum pressure
Minimum pressure
Hot water quantity with ∆t 25°C
with ∆t 30°C
with ∆t 35°C
DHW minimum output
Selection field of DHW temperature
Flow regulator
Gas pressure
Methane gas nominal pressure (G20)
LPG liquid gas nominal pressure (G30)
LPG liquid gas nominal pressure (G31)
Hydraulic connections
Heating input - output
DHW input-output
Gas input
Boiler dimensions
Height
Width
Depth of housing
Boiler weight
Flow rate (G20)
Air capacity
Flue gas capacity
Mass flow of flue gas (max-min)
Flow rate (G30)
Air capacity
Flue gas capacity
Mass flow of flue gas (max-min)
All manuals and user guides at all-guides.com
kW
kcal/h
kW
kcal/h
kW
kcal/h
kW
kcal/h
kW
kcal/h
kW
kcal/h
kW
kcal/h
kW
kcal/h
%
%
%
W
W
V - Hz
IP
%
%
bar
bar
°C
mbar
l/h
l
bar
bar
bar
l/min
l/min
l/min
l/min
°C
l/min
mbar
mbar
mbar
Ø
Ø
Ø
mm
mm
mm
kg
Nm
Nm
g/s
Nm
Nm
g/s
Mynute S 24 C.A.I. E
26,70
22.962
23,98
20.620
10,70
9.202
9,14
7.859
26,70
22.962
23,98
20.620
8,30
7.138
7,09
6.096
89,8-85,4
89,5
91,1
56
40
II2H3+
(+)
230-50
X5D
8,90
0,30
3 - 90
0,25 - 0,45
40/80
227
1.000
9
1
6
0,15
13,7
11,5
9,8
2
37/60
10
20
28-30
37
3/4"
1/2"
3/4"
740
400
332
30
h
44,666
3/
/h
47,345
3
16,115-15,926
h
43,235
3/
/h
44,020
3
15,033-14,182
Mynute S C.A.I. E
Mynute S 28 C.A.I. E
31,90
27.434
28,71
24.691
14,00
12.040
11,93
10.258
31,90
27.434
28,71
24.691
8,70
7.482
7,41
6.375
90,0-85,2
89,5
91,2
54
40
II2H3+
(+)
230-50
X5D
8,83
0,27
3 - 90
0,25 - 0,45
40/80
227
1.000
9
1
6
0,15
16,5
13,7
11,8
2
37/60
12
20
28-30
37
3/4"
1/2"
3/4"
740
450
332
32
50,960
54,160
18,855 -16,978
48,088
50,432
17,868-15,833