22 | English
Press and hold the 
If no button on the measuring tool is pressed for approx. 5 min, the measuring tool will
switch off automatically to preserve the non-rechargeable batteries.
All stored values are retained when the tool is switched off.

Measuring Process

Once switched on, the measuring tool is in the length measurement function.
Once the measuring tool has been switched on, the rear edge of the measuring tool is se-
lected as the reference level for measurement. You can change the reference level. (see
"Selecting the Reference Level", page 22)
Apply the measuring tool to the point at which you want to start the measurement (e.g.
wall).
Press the 
button to switch on the laser beam.
Target the target surface with the laser beam.
Briefly press the 
button again to start the measurement.
In the continuous measurement function, the measurement begins immediately after the
first press of the 
button.
For more information, you can access the online operating instructions at
www.bosch-pt.com/manuals
The measuring tool must not be moved during a measurement (with the exception
of the continuous measurement and grade measurement functions). Therefore,
place the measuring tool, as far as this is possible, against or on a firm stop or supporting
surface.
The reception lens (9) and the laser beam output (8) must not be covered during
the measuring process.
Selecting the Reference Level
For the measurement, you can select from various reference levels:
The rear edge of the measuring tool (e.g. when placing against walls)
1 609 92A 7HD | (14.03.2022)
button to switch off the measuring tool.
Bosch Power Tools