Verfügbare Sprachen

The adjustment of the regulating
function, must be done by a qualified
electrician. The knob and the front
first have to be removed. Disconnect
from power supply before removing.
Then slide the control to the
required position using a small
screwdriver.
The overheating protection is adjusted here.
The regulating function is adjusted here.
R - Room thermostat
F - Floor thermostat
R&F - Room and floor thermostat