NB3711
NRSW-Benutzerhandbuch - Version 4.6.0.100
3.4.10. Digital Inputs and Outputs
The isolated input and oputput ports have the following specification in common:
Funktion
Isolation to enclosure/GND
Isolation to adjacent I/O
Max. cable length
Cable shield
Isolated Outputs
The isolated digital output ports have the following specification:
Funktion
Number of output ports
Limiting continuous current
Maximum switching voltage
Maximum switching capacity
Isolated Inputs
The isolated digital input ports have the following specification:
Funktion
Number of inputs
Maximum input voltage
Minimum voltage for level 1
(set)
Maximum voltage for level 0
(not set)
Note: A negative input voltage is not recognized.
Pin Assignment M12 8-pole A-coded female
Spezifikation
1'000 V
functional
10 m
not required
Tabelle 3.18.: Common Digital I/O Specification
Spezifikation
2
1 A
60 V
60 W
Tabelle 3.19.: Isolated Digital Outputs Specification
Spezifikation
2
40 V
7.2 V
5.0 V
Tabelle 3.20.: Isolated Digital Inputs Specification
AC
, 42 V
( V
)
DC
AC
rms
DC
DC
DC
29