3.3. Environmental Conditions

Parameter
Input Voltage (Variant Pa)
Input Voltage (Variant Pb)
Operating Temperature Range
Storage Temperature Range
Humidity
Altitude (Variant Pa)
Altitude (Variant Pb)
Over-Voltage Category
Pollution Degree
Ingress Protection Rating
Attention: When using the Pb variant with an input voltage higher than 60 V
MUST be connected to an earth protection.
Rating
24 V
to 48 V
DC
72 V
to 110 V
DC
24-48 V
max. 5 radio modules
72-110 V
max. 3 radio modules
72-110 V
max. 4 radio modules
40 C to +85 C
0 to 95% (non-condensing)
up to 4000m
up to 2000m
I
2
IP40 (with SIM and USB covers mounted)
Tabelle 3.1.: Environmental Conditions